Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "Talk:MitoFit Proficiency Test"

From Bioblast
Β 
(30 intermediate revisions by 5 users not shown)
Line 2: Line 2:




== Important information for the MitoFit Proficiency Test ==
== Important information for the MitoFit Proficiency Test (PT) ==


'''Required equipment:'''
'''Required equipment:'''
Line 12: Line 12:


'''Chemicals:'''
'''Chemicals:'''
::::* [[SUIT-RP1]]:
::::* for [[SUIT-001_O2_ce-pce_D003 |SUIT-RP1]] and for [[SUIT-002 O2 ce-pce D007 |SUIT-RP2]]:
::::* [[SUIT-RP2]]:
::::Β» [[Digitonin]], [[Pyruvate]], [[Malate]], [[ADP]], [[Cytochrome c]], [[CCCP]], [[Glutamate]], [[Succinate]], [[Octanoylcarnitine]], [[Rotenone]], [[Glycerophosphate]], [[Antimycin A]]
::::* ADP and Digitonin will be provided.
Β 
Β 
:::: We are aware that the Quality Control of the chemicals is a key factor influencing the results of the MitoFit Proficiency test. For the present test, however, due to logistic limitations, participants are asked to perform tests using their own chemicals. For future tests, provision of critical chemicals is planned. Should the lack of some chemicals be the main reason why you do not see fit to participate in the current round, we kindly ask for your feedback and see if we can solve the issue. We will try to solve any problems. Β 




Line 20: Line 22:
::::* '''individually''' (one O2k instrument per participant)
::::* '''individually''' (one O2k instrument per participant)
::::* without any further help
::::* without any further help
::::* Manuals and SOPs can be used, see: [[O2k-technical_support_and_open_innovation]]
::::* Manuals and SOPs can be used, see: [[O2k-Open Support]]






''' Beginner or advanced user? - Self assessment:'''
''' Registration form and self assessment:'''
:::: Please indicate if you are a beginner or an advanced O2k user, filling out the questionnaire:
:::: [[File:PDF.jpg|100px|link=http://wiki.oroboros.at/index.php/File:Registration_form_MitoFit_Proficiency_test.pdf |MitoFit PT pdf]] Β 
Β 
Β 
:::: Send the questionnaire to [mailto:instruments@oroboros.at|instruments@oroboros.at]


:::: Send the registration form to [mailto:[email protected] [email protected]]


== Time schedule ==
== Time schedule ==


=== Round 01 - ## participants ===
=== Round 01 - 20 labs invited ===


{| class="wikitable"
{| class="wikitable"
Line 40: Line 40:
! Β 
! Β 
|-
|-
| 2018-10-09
| 2018-10-11
| DatLab 7.3 and instructions to be sent to the participants of the study
| DatLab 7.3 and instructions to be sent to the participants of the study
|-
|-
| 2018-10-10 to 15
| 2018-10-12 to 15
| '''Level I'''PT to be performed: instrumental background oxygen flux and air calibration, using the Instrumental DLPs
| '''Level I PT''' to be performed: instrumental background oxygen flux and air calibration, using the Instrumental DLPs
Shipping of HEK cells
|-
|-
| 2018-10-15
| 2018-10-16
| DatLab Files have to be sent to [mailto:[email protected] [email protected]]
| DatLab Files have to be sent to [mailto:[email protected] [email protected]]
Shipping of HEK cells
|-
|-
| 2018-10-17
| 2018-10-17
Line 54: Line 54:
Feedback on Level I sent to participants
Feedback on Level I sent to participants
|-
|-
| 2018-10-17 to 26
| 2018-10-18 to 26
| '''Level II''' PT to be performed: SUIT 1 / 2 technical repeats
| '''Level II PT''' to be performed: SUIT RP 1/2, technical repeats
|-
|-
| 2018-10-28
| 2018-10-29
| DatLab files to be sent to Oroboros for analysis (Level II)
| DatLab files to be sent to Oroboros for analysis (Level II)
|-
|-
| 2018-10-31
| 2018-11-09
| Feedback to the participants
| Report sent to the participants
|-
|-


|}
|}


== Scientific objective ==
== Scientific objective ==


'''Is there any scientific objective?'''
:::: Together with a literature review and preliminary data from the Oroboros MitoFit laboratory, we are going to publish the test results in collaboration with the Department for Medical Statistics, Informatics and Health Economics, Medical University of Innsbruck, as part of the K-Regio Project MitoFit.
:::: Together with a literature review and preliminary data from the Oroboros MitoFit laboratory, we are going to publish the test results in collaboration with the Department for Medical Statistics, Informatics and Health Economics, Medical University of Innsbruck, as part of the K-Regio Project MitoFit.
:::: With the participation in the MitoFit Proficiency Test, you agree on the use of experimental data collected for the test, to be used for research purposes in an anonym way. Β 
:::: With the participation in the MitoFit Proficiency Test, you agree on the use of experimental data collected for the test, to be used for research purposes in an anonymized way.
Β 


== Time requirements ==
== Time requirements ==


'''How much time is needed for the execution of the test?'''
:::: '''Level 1.''' Air calibration and Instrumental background oxygen flux: ca. 3 hours
:::: Level 1. Air calibration and Instrumental background oxygen flux: ca. 3 hours
:::: '''Level 2.''' [[SUIT-001]] or [[SUIT-002]]: ca. 3 hours, including air calibration
:::: Level 2. SUIT-1 or SUIT-2: ca. 3 hours, including air calibration
:::: '''Level 3.''' Data analysis: 1 hour
:::: Level 3. Data analysis: 1 hour
:::: Within the timespan of one workday, your personal proficiency is comprehensively evaluated, using your own O2k and your laboratory equipment.
:::: Within the timespan of one workday, your personal proficiency is comprehensively evaluated, using your own O2k and your laboratory equipment
Β 


== Additional support ==
== Additional support ==




'''Additional resources:'''
::::* For a comprehensive list of DatLab menus: [[MitoPedia:_DatLab|MitoPedia DatLab]]
:::: For a comprehensive list of DatLab menus: [[MitoPedia:_DatLab|MitoPedia DatLab]]
::::* [[MitoPedia:_SUIT| MitoPedia - SUIT]]
:::: [[MitoPedia:_SUIT| MitoPedia - SUIT]]
::::* [[MiPNet19.18E_O2_flux_analysis_-_DatLab_6|Flux analysis]]
:::: [[MiPNet19.18E_O2_flux_analysis_-_DatLab_6|Flux analysis]]
::::* [[Run_DL-Protocol/Set_O2_limit|DatLab Protocols, DLP: List of titrations, marks, overview on the website]].
:::: DatLab Protocols, DLP: List of titrations, marks, overview on the website.

Latest revision as of 16:52, 28 May 2019


Important information for the MitoFit Proficiency Test (PT)

Required equipment:


Chemicals:

Β» Digitonin, Pyruvate, Malate, ADP, Cytochrome c, CCCP, Glutamate, Succinate, Octanoylcarnitine, Rotenone, Glycerophosphate, Antimycin A


We are aware that the Quality Control of the chemicals is a key factor influencing the results of the MitoFit Proficiency test. For the present test, however, due to logistic limitations, participants are asked to perform tests using their own chemicals. For future tests, provision of critical chemicals is planned. Should the lack of some chemicals be the main reason why you do not see fit to participate in the current round, we kindly ask for your feedback and see if we can solve the issue. We will try to solve any problems.


Experiments are to be performed:

  • individually (one O2k instrument per participant)
  • without any further help
  • Manuals and SOPs can be used, see: O2k-Open Support


Registration form and self assessment:

MitoFit PT pdf
Send the registration form to [email protected]

Time schedule

Round 01 - 20 labs invited

Date
2018-10-11 DatLab 7.3 and instructions to be sent to the participants of the study
2018-10-12 to 15 Level I PT to be performed: instrumental background oxygen flux and air calibration, using the Instrumental DLPs

Shipping of HEK cells

2018-10-16 DatLab Files have to be sent to [email protected]
2018-10-17 Arrival of shipment at customer’s site at the latest

Feedback on Level I sent to participants

2018-10-18 to 26 Level II PT to be performed: SUIT RP 1/2, technical repeats
2018-10-29 DatLab files to be sent to Oroboros for analysis (Level II)
2018-11-09 Report sent to the participants

Scientific objective

Together with a literature review and preliminary data from the Oroboros MitoFit laboratory, we are going to publish the test results in collaboration with the Department for Medical Statistics, Informatics and Health Economics, Medical University of Innsbruck, as part of the K-Regio Project MitoFit.
With the participation in the MitoFit Proficiency Test, you agree on the use of experimental data collected for the test, to be used for research purposes in an anonymized way.

Time requirements

Level 1. Air calibration and Instrumental background oxygen flux: ca. 3 hours
Level 2. SUIT-001 or SUIT-002: ca. 3 hours, including air calibration
Level 3. Data analysis: 1 hour
Within the timespan of one workday, your personal proficiency is comprehensively evaluated, using your own O2k and your laboratory equipment.

Additional support