Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "SUIT-001 O2 ce-pce D003"

From Bioblast
Line 6: Line 6:
|SUIT number=D003_ce1;1Dig;1PM;2D;2c;3U;4G;5S;6Oct;7Rot;8Gp;9Ama;10AsTm;11Azd
|SUIT number=D003_ce1;1Dig;1PM;2D;2c;3U;4G;5S;6Oct;7Rot;8Gp;9Ama;10AsTm;11Azd
}}
}}
::: '''[[MitoPedia: SUIT]]''' - '''[[SUIT reference protocol]] RP1 for non-permeabilized cells'''
::: '''[[MitoPedia: SUIT]]''' - '''[[SUIT reference protocol]] RP1 for cells that are permeabilized in the chamber'''
::: '''[[Categories of SUIT protocols |SUIT-category]]:''' FNSGp(Oct,PGM)
::: '''[[Categories of SUIT protocols |SUIT-category]]:''' FNSGp(Oct,PGM)
::: '''[[SUIT protocol pattern]]:''' orthogonal 1PM;2D;2c;3U;4G;5S;6Oct;7Rot;8Gp-
::: '''[[SUIT protocol pattern]]:''' orthogonal 1PM;2D;2c;3U;4G;5S;6Oct;7Rot;8Gp-


The SUIT-001 O2 ce-pce D003 protocol in combination with [[SUIT-002 O2 ce-pce D007]] is specially designed to provide a common reference for comparison of respiratory control of [[Permeabilized cells| permeabilized cells]] (the cells added to the chamber must not be permeabilized because the permeabilization is performed into the chambers) in a wide variety of cell types. SUIT-001 O2 ce-pce D003 gives information of [[ROUTINE]] respiration (ce: non-permeabilized cells) and after the plasma membrane permeabilization (pce: permeabilized cells) of linear coupling control ([[LEAK-respiration|''L'']]-[[Oxidative phosphorylation| ''P'']]-[[ET-capacity| ''E'']]) with NADH linked-substrates ([[PM pathway control state|PM]]). Moreover, the pathway control in ET state ([[NADH_Electron_transfer-pathway_state|N]], [[NS-pathway control state| NS]], [[FNS]], [[Succinate pathway control state| S]] and [[SGp-pathway control state| SGp]] pathways) can be evaluated by using this SUIT protocol. SUIT-001 O2 pce D003 can be extended with the CIV assay module.
The SUIT-001 O2 ce-pce D003 protocol in combination with [[SUIT-002 O2 ce-pce D007]] is specially designed to provide a common reference for comparison of respiratory control of [[Permeabilized cells| permeabilized cells]] (non-permeabilized cells must be added to the chambers and then permeabilized as a part of the protocol) in a wide variety of cell types. SUIT-001 O2 ce-pce D003 gives information of [[ROUTINE]] respiration (ce: non-permeabilized cells) and after the plasma membrane permeabilization (pce: permeabilized cells) of linear coupling control ([[LEAK-respiration|''L'']]-[[Oxidative phosphorylation| ''P'']]-[[ET-capacity| ''E'']]) with NADH linked-substrates ([[PM pathway control state|PM]]). Moreover, the pathway control in ET state ([[NADH_Electron_transfer-pathway_state|N]], [[NS-pathway control state| NS]], [[FNS]], [[Succinate pathway control state| S]] and [[SGp-pathway control state| SGp]] pathways) can be evaluated by using this SUIT protocol. SUIT-001 O2 pce D003 can be extended with the CIV assay module.




Line 35: Line 35:
:::+ If NS- and FNS-pathways are similar (NS<sub>''E''</sub> ~ FNS<sub>''E''</sub>), the additivity index of N- and S-pathways in ET state can be evaluated.  
:::+ If NS- and FNS-pathways are similar (NS<sub>''E''</sub> ~ FNS<sub>''E''</sub>), the additivity index of N- and S-pathways in ET state can be evaluated.  
:::+ This protocol can be extended with the Complex IV module.
:::+ This protocol can be extended with the Complex IV module.
:::+ The addition of non-permeabilized cells to the chambers provides additional information ([[ROUTINE]] respiration) respect to the [[SUIT-001 O2 mt D001]] where the cells added to the chambers are already permeabilized.
:::+ The addition of non-permeabilized cells to the chambers provides additional information ([[ROUTINE]] respiration) which can not be obtained in [[SUIT-001 O2 mt D001]] where the cells added to the chambers are already permeabilized.


:::- The substrate combination for maximum ET capacity (FNSGP) is not obtained in SUIT-001 in favour of measuring S<sub>''E''</sub>.
:::- The substrate combination for maximum ET capacity (FNSGP) is not obtained in SUIT-001 in favour of measuring S<sub>''E''</sub>.
Line 46: Line 46:
::::* [[SUIT-002 O2 pce D007]] (RP2): Harmonized SUIT protocol for permeabilized cells.
::::* [[SUIT-002 O2 pce D007]] (RP2): Harmonized SUIT protocol for permeabilized cells.


::::* [[SUIT-001 O2 mt D001]]: SUIT-001 for permeabilized cells (the cells added to the chamber must be already permeabilized). This SUIT protocol provides only information of permeabilized cells (pce).
::::* [[SUIT-001 O2 mt D001]]: SUIT-001 for permeabilized cells (cells added to the chamber have been permeabilized before their addition). This SUIT protocol provides no information on [[ROUTINE]] respiration of intact cells (ce).


::::* [[SUIT-004]]: Short version of RP1; without G, F and Gp.
::::* [[SUIT-004]]: Short version of RP1; without G, F and Gp.

Revision as of 14:44, 27 March 2019


high-resolution terminology - matching measurements at high-resolution


SUIT-001 O2 ce-pce D003

Description

SUIT-RP1

Abbreviation: FNSGp(Oct,PGM)

Reference: A Reference protocol RP1; ce: non-permeabilized cells, pce: permeabilized cells - SUIT-001

SUIT number: D003_ce1;1Dig;1PM;2D;2c;3U;4G;5S;6Oct;7Rot;8Gp;9Ama;10AsTm;11Azd

O2k-Application: O2

MitoPedia: SUIT - SUIT reference protocol RP1 for cells that are permeabilized in the chamber
SUIT-category: FNSGp(Oct,PGM)
SUIT protocol pattern: orthogonal 1PM;2D;2c;3U;4G;5S;6Oct;7Rot;8Gp-

The SUIT-001 O2 ce-pce D003 protocol in combination with SUIT-002 O2 ce-pce D007 is specially designed to provide a common reference for comparison of respiratory control of permeabilized cells (non-permeabilized cells must be added to the chambers and then permeabilized as a part of the protocol) in a wide variety of cell types. SUIT-001 O2 ce-pce D003 gives information of ROUTINE respiration (ce: non-permeabilized cells) and after the plasma membrane permeabilization (pce: permeabilized cells) of linear coupling control (L- P- E) with NADH linked-substrates (PM). Moreover, the pathway control in ET state (N, NS, FNS, S and SGp pathways) can be evaluated by using this SUIT protocol. SUIT-001 O2 pce D003 can be extended with the CIV assay module.


Communicated by Doerrier C and Gnaiger E (last update 2019-03-27)
MitoPedia: SUIT

Steps and respiratory states

SUIT-001

Step State Pathway Q-junction Comment - Events (E) and Marks (M)
ce1 ROUTINE ce1
  • ROUTINE respiration in the physiological coupling state R. Externally added permeable substrates could contribute to this respiratory state.
1Dig REN ce1;1Dig
  • Optimum effective digitonin concentration for complete plasma membrane permeabilization.
Step State Pathway Q-junction Comment - Events (E) and Marks (M)
1PM PML(n) N CI 1PM
2D PMP N CI 1PM;2D
2c PMcP N CI 1PM;2D;2c
3U PME N CI 1PM;2D;3U
4G PGME N CI 1PM;2D;3U;4G
5S PGMSE NS CI&II 1PM;2D;3U;4G;5S
6Oct OctPGMSE FNS FAO&CI&II 1PM;2D;3U;4G;5S;6Oct
  • Respiratory stimulation by simultaneous action of the F-pathway, N-pathway, and S-pathway, with convergent electron flow in the FNS-pathway for reconstitution of TCA cycle function and additive or inhibitory effect of F.
  • Noncoupled electron transfer state, ET state, with ET capacity E.
7Rot SE S CII 1PM;2D;3U;4G;5S;6Oct;7Rot
8Gp SGpE SGp CII&GpDH 1PM;2D;3U;4G;5S;6Oct;7Rot;8Gp
  • Respiratory stimulation by action of succinate and glycerophosphate, Gp, with convergent electron flow in the SGp-pathway (CII&GpDH-linked pathway to the Q-junction).
  • Noncoupled electron transfer state, ET state, with ET capacity E.
9Ama ROX
  • Rox is the residual oxygen consumption in the ROX state, due to oxidative side reactions, estimated after addition of antimycin A (inhibitor of CIII). Rox is subtracted from oxygen flux as a baseline for all respiratory states, to obtain mitochondrial respiration (mt).
Step Respiratory state Pathway control ET-Complex Comment
## AsTm AsTmE CIV CIV
## Azd CHB


Questions.jpg


Click to expand or collaps

Strengths and limitations

  • SUIT-001 in combination with SUIT-002 provides a common reference for comparison of respiratory control in a large variety of species, tissues and cell types. Both SUIT protocols provide a mitochondrial mapping which allows:
1. to obtain reference values.
2. to evaluate mitochondrial physiological diversity, generating a mt-database on comparative mitochondrial physiology.
3. to screen specific defects.
  • SUIT-001 and SUIT-002 are used in the MitoFit Proficiency test for inter-individual and inter-laboratory reproducibility quality control.
  • A succinate concentration of >10 mM may be required for saturating SE capacity.
+ Linear coupling control (L-P-E) with N substrates (PM).
+ Pathway control in ET state (N, NS, FNS, S and SGp pathways).
+ Harmonization with SUIT-002 allows to perform both SUIT protocols in parallel. The cross-linked respiratory states can be statistically used as repeated measurements.
+ In cells, SUIT-001 and SUIT-002 harmonize in: ROUTINE (ce1), SGpE (8Gp in SUIT-001 and 10Rot in SUIT-002) and Complex IV.
+ Harmonization with many SUIT protocols (up to step 5S).
+ Oct is added in ET state to avoid uncoupler effect with fatty acids.
+ If NS- and FNS-pathways are similar (NSE ~ FNSE), the additivity index of N- and S-pathways in ET state can be evaluated.
+ This protocol can be extended with the Complex IV module.
+ The addition of non-permeabilized cells to the chambers provides additional information (ROUTINE respiration) which can not be obtained in SUIT-001 O2 mt D001 where the cells added to the chambers are already permeabilized.
- The substrate combination for maximum ET capacity (FNSGP) is not obtained in SUIT-001 in favour of measuring SE.
- Lengthy duration of the experiment.

Compare SUIT protocols

  • SUIT-001 O2 pce D004: SUIT-001 O2 pce D003 (general SUIT-001 for permeabilized cells) differs from SUIT-001 O2 pce D004 (SUIT-001 for permeabilized PBMCs and PLTs) in the presence and absence of octanoylcarnitine, respectively.
  • SUIT-001 O2 mt D001: SUIT-001 for permeabilized cells (cells added to the chamber have been permeabilized before their addition). This SUIT protocol provides no information on ROUTINE respiration of intact cells (ce).
  • SUIT-004: Short version of RP1; without G, F and Gp.
  • SUIT-006: Very short initial coupling control module.

References

MitoPedia concepts: SUIT protocol, SUIT A, Find 


MitoPedia methods: Respirometry