:::: Switching between different excitation wavelengths and filters is achieved by simply exchanging the Fluo-Sensors. Two types of optical sensors are supplied with different LEDs for fluorescence excitation, and the effective spectra of the LEDs are modified by filters.
:::: Switching between different excitation wavelengths and filters is achieved by simply exchanging the Fluo-Sensors. Two types of optical sensors are supplied with different LEDs for fluorescence excitation, and the effective spectra of the LEDs are modified by filters.
:::: Select the Fluo-Sensor and filter set from the table on [https://wiki.oroboros.at/index.php/O2k-Fluo_LED2-Module#Fluorophores application-specific settings] (here we should link to the respective section which is also a template). Each Fluo-Sensor is delivered with a mounted filter set:  
:::: Select the Fluo-Sensor and filter set from the table on [https://wiki.oroboros.at/index.php/O2k-Fluo_LED2-Module#Fluorophores application-specific settings] (here we should link to the respective section which is also a template). Each Fluo-Sensor is delivered with a mounted filter set:  
::::# Fluo-Sensor Green (links to product pages)[[Smart Fluo-Sensor Green]]: 525 nm (dominant wavelength). The installed Filter-Cap is ready for H<sub>2</sub>O<sub>2</sub> measurement with [[Amplex red|Amplex® UltraRed]] or for measurements of mt-membrane potential with [[TMRM]].
::::# Fluo-Sensor Green (links to product pages?)[[Smart Fluo-Sensor Green]]: 525 nm (dominant wavelength). The installed Filter-Cap is ready for H<sub>2</sub>O<sub>2</sub> measurement with [[Amplex red|Amplex® UltraRed]] or for measurements of mt-membrane potential with [[TMRM]].
::::# Fluo-Sensor Blue (links to product pages? [[Smart Fluo-Sensor Blue]]: 465 nm (dominant wavelength). The installed Filter-Cap is ready for measurements of mt-membrane potential with [[safranin]] or [[Rhodamine 123]]. A different filter is used for measurement with [[Magnesium green|Magnesium Green™]] or Calcium Green™.
::::# Fluo-Sensor Blue (links to product pages?) [[Smart Fluo-Sensor Blue]]: 465 nm (dominant wavelength). The installed Filter-Cap is ready for measurements of mt-membrane potential with [[safranin]] or [[Rhodamine 123]]. A different filter is used for measurement with [[Magnesium green|Magnesium Green™]] or Calcium Green™.

Revision as of 17:13, 18 November 2021

Select the Fluo-Sensors

Switching between different excitation wavelengths and filters is achieved by simply exchanging the Fluo-Sensors. Two types of optical sensors are supplied with different LEDs for fluorescence excitation, and the effective spectra of the LEDs are modified by filters.
Select the Fluo-Sensor and filter set from the table on application-specific settings (here we should link to the respective section which is also a template). Each Fluo-Sensor is delivered with a mounted filter set:
  1. Fluo-Sensor Green (links to product pages?)Smart Fluo-Sensor Green: 525 nm (dominant wavelength). The installed Filter-Cap is ready for H2O2 measurement with Amplex® UltraRed or for measurements of mt-membrane potential with TMRM.
  2. Fluo-Sensor Blue (links to product pages?) Smart Fluo-Sensor Blue: 465 nm (dominant wavelength). The installed Filter-Cap is ready for measurements of mt-membrane potential with safranin or Rhodamine 123. A different filter is used for measurement with Magnesium Green™ or Calcium Green™.