Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "Smart Fluo-Sensor Blue"

From Bioblast
Line 1: Line 1:
{{Product
{{Product
|description='''Smart Fluo-Sensor Blue''': Excitation LED 465 nm (dominant wavelenght), individual sensors are calibrated with sensor-specific memory and direct input into DatLab 7 to obtain reproducible light intensities with different sensors, including photodiode, [[Filter-Cap]] equipped with [[Filter Set Saf]] for [[Safranin|safranin]] and [[Rhodamine 123|rhodamine 123]] measurements and [[Filter Set MgG / CaG]] for [[Magnesium green]] and [[Calcium green]] when delivered. Β 
|description='''Smart Fluo-Sensor Blue''': Excitation LED 465 nm (dominant wavelenght), individual sensors are calibrated with sensor-specific memory and direct input into DatLab 7 to obtain reproducible light intensities with different sensors, including photodiode, [[Filter-Cap]] equipped with [[Filter Set Saf]] for measurement of mitochondrial membrane potential with [[Safranin|safranin]] and [[Rhodamine 123|rhodamine 123]]. [[Filter Set MgG / CaG]] for [[Magnesium green]] and [[Calcium green]] measurements are included. Β 


Two units of this item are standard components of the [[O2k-FluoRespirometer]] and the [[Upgrade of O2k-Respirometer to O2k-FluoRespirometer]]. Smart Fluo-Sensors can be used with O2k-Series H and higher.
Two units of this item are standard components of the [[O2k-FluoRespirometer]] and the [[Upgrade of O2k-Respirometer to O2k-FluoRespirometer]]. Smart Fluo-Sensors can be used with O2k-Series H and higher.

Revision as of 12:39, 28 May 2019

                



Smart Fluo-Sensor Blue

O2k-Catalogue

Description Smart Fluo-Sensor Blue: Excitation LED 465 nm (dominant wavelenght), individual sensors are calibrated with sensor-specific memory and direct input into DatLab 7 to obtain reproducible light intensities with different sensors, including photodiode, Filter-Cap equipped with Filter Set Saf for measurement of mitochondrial membrane potential with safranin and rhodamine 123. Filter Set MgG / CaG for Magnesium green and Calcium green measurements are included.

Two units of this item are standard components of the O2k-FluoRespirometer and the Upgrade of O2k-Respirometer to O2k-FluoRespirometer. Smart Fluo-Sensors can be used with O2k-Series H and higher.

Product ID 44222-01
Type O2k-FluoRespirometer, Power O2k-FluoRespirometer
Link Smart Fluo-Sensor
Image
SmartFluo.png