OroboPOS-Membranes MitoPedia: Difference between revisions

From Bioblast
(Created page with "{{MitoPedia |abbr=FEP-membranes |description='''OroboPOS-Membranes''', FEP 25 ยตm; 40/Pck. Two packages of this item (26200-01) are standard components of the OroboPO...")
ย 
No edit summary
Line 1: Line 1:
{{MitoPedia
{{MitoPedia
|abbr=FEP-membranes
|abbr=FEP-membranes
|description='''[[OroboPOS]]-Membranes''', FEP 25 ยตm; 40/Pck. ย  Two packages of this item (26200-01) are standard components of the [[OroboPOS-Service Kit]].
|description=[[Image:POS membranes.jpg|right|180px]]
|info=[[OroboPOS-Membranes]]
'''[[OroboPOS]]-Membranes''', FEP 25 ยตm; 40/Pck. Two packages of this item (26200-01) are standard components of the [[OroboPOS-Service Kit]].
|info=[[OroboPOS-Membranes]], [[MiPNet08.04]]
}}
}}
{{MitoPedia concepts}}
== Storage of OroboPOS-Membranes ==
{{MitoPedia methods}}
ย 
::::* The OroboPOS-Membranes are stored in the boxes containing originally 40 membranes per package. Each transparent FEP membrane (TEFLON<sup>ยฎ</sup> FEP) is sandwiched between two white circular paper covers, which prevent the FEP membranes from sticking together. A FEP membrane can be used only once and must not be place back into the membrane box after use. Close the membrane box carefully after removing a membrane, and avoid any external contamination of the unused FEP membranes stored in the box. Under these conditions, the storage time of FEP membranes is practically unlimited.
ย 
{{MitoPedia O2k and high-resolution respirometry
{{MitoPedia O2k and high-resolution respirometry
|mitopedia O2k and high-resolution respirometry=O2k hardware
|mitopedia O2k and high-resolution respirometry=O2k hardware
}}
}}
{{MitoPedia topics}}
== Storage of OroboPOS-Membranes ==
::::* The OroboPOS-Membranes are stored in the boxes containing originally 40 membranes per package. Each transparent FEP membrane (TEFLON<sup>ยฎ</sup> FEP) is sandwiched between two white circular paper covers, which prevent the FEP membranes from sticking together. A FEP membrane can be used only once and must not be place back into the membrane box after use. Close the membrane box carefully after removing a membrane, and avoid any external contamination of the unused FEP membranes stored in the box. Under these conditions, the storage time of FEP membranes is practically unlimited.

Revision as of 10:08, 3 September 2020


high-resolution terminology - matching measurements at high-resolution


OroboPOS-Membranes MitoPedia

Description

POS membranes.jpg

OroboPOS-Membranes, FEP 25 ยตm; 40/Pck. Two packages of this item (26200-01) are standard components of the OroboPOS-Service Kit.

Abbreviation: FEP-membranes

Reference: OroboPOS-Membranes, MiPNet08.04

Storage of OroboPOS-Membranes

  • The OroboPOS-Membranes are stored in the boxes containing originally 40 membranes per package. Each transparent FEP membrane (TEFLONยฎ FEP) is sandwiched between two white circular paper covers, which prevent the FEP membranes from sticking together. A FEP membrane can be used only once and must not be place back into the membrane box after use. Close the membrane box carefully after removing a membrane, and avoid any external contamination of the unused FEP membranes stored in the box. Under these conditions, the storage time of FEP membranes is practically unlimited.


MitoPedia O2k and high-resolution respirometry: O2k hardware 

Cookies help us deliver our services. By using our services, you agree to our use of cookies.