Search results
From Bioblast
Page title matches
- ...etting started with the [[Oroboros O2k]] to guarantee a standard [[chamber volume]] of 2.0 mL.380 bytes (49 words) - 11:57, 25 March 2022
- #REDIRECT [[O2k chamber volume calibration]]44 bytes (6 words) - 10:05, 14 August 2016
Page text matches
- ...<span style="font-size:105%; color:##424242"> '''Β»Bioblast links: Chamber volume''' - >>>>>>> - Click on [Expand] or [Collapse] - >>>>>>></span> ::::Β» '''[[Volume]]'''2 KB (208 words) - 17:53, 18 October 2020
- ...]]'''Volume-Calibration Ring''' (A or B) PVDF for O2k-Stoppers (2-mL [[O2k-chamber]]), white; attached to the [[Stopper\black PEEK\conical Shaft\central Port |info=[https://www.oroboros.at/index.php/product/volume-calibration-ring/ '''Product details and purchase information''']1 KB (171 words) - 11:53, 11 November 2020
- ...ge:Volume calibration ring A+B PVDF for Stopper.jpg|right|180px]]'''Volume-Calibration Ring sV''' (A or B), white PVDF, attached to [[Stopper sV\black PEEK\conica |info=[https://www.oroboros.at/index.php/product/volume-calibration-ring-sv/ '''Product details and purchase information''']1 KB (184 words) - 11:25, 11 November 2020
- ...etting started with the [[Oroboros O2k]] to guarantee a standard [[chamber volume]] of 2.0 mL.380 bytes (49 words) - 11:57, 25 March 2022
- :::* Version 08 (2020-10-17) Section '''5.4. O2k-chamber volume calibration''' ::::# Instructions are added for the 0.5-mL O2k-chamber volume calibration ([[O2k-sV-Module]]).2 KB (198 words) - 11:43, 27 July 2023
- |description='''Volume calibration ring PVDF M2.5''' (A or B) PVDF for O2k-Stopper sV, white; attached to the |product image=TO REPACE [[Image:Volume calibration ring A+B PVDF for Stopper.jpg|right|180px]]1 KB (212 words) - 11:19, 6 November 2019
- ....be/1MSsI1ePMu8]] [https://youtu.be/1MSsI1ePMu8 Chamber service Insert O2k Chamber] ...equired for regular [[MiPNet19.03 O2k-cleaning and ISS |cleaning the glass chamber]].4 KB (628 words) - 18:07, 6 December 2017
- ...iological sample, and all the components necessary for a smaller operation volume ''V'' of 0.5 mL. The current DatLab version is included in the delivery of == Titration to the 0.5-mL O2k-chamber ==3 KB (426 words) - 10:05, 14 September 2023
- ...1.3 mm diameter; 50.6 mm length), [[Volume-Calibration Ring]] (A or B) for volume adjustment 1.5 to 3.2 ml; 2 mounted O-rings, with 8 spare O-rings ([[O-ring ...O2k-FluoRespirometer manual]] for calibration of the 2-mL [[O2k-chamber]] volume, which is identical for PEEK and PVDF stoppers.1 KB (177 words) - 10:43, 11 November 2020
- ...tential causes for '''different O<sub>2</sub> fluxes in the left and right chamber'''? ...experiments we get consistently higher fluxes in chamber A as compared to chamber B.2 KB (341 words) - 18:56, 6 November 2019
- ...mm diameter; 48.9 mm length), [[Volume-Calibration Ring sV]] (A or B) for volume adjustment 0.5 mL; 2 mounted O-rings ([[O-ring sV\Viton\9.5x1 mm]]). {{Template:Keywords: Chamber volume}}776 bytes (95 words) - 10:43, 18 November 2020
- ...1ePMu8&list=PLT4umseflf-m6O1sApyn9doi8vHNAKaIs&index=3 '''A2''' Insert O2k Chamber] ...be/zZI7O5zAruw]] [https://youtu.be/zZI7O5zAruw '''A4''' O2k-chamber volume calibration]9 KB (1,435 words) - 12:42, 14 November 2023
- ...rol (standard 30 s) with 30 min time scale displayed with Graph Layout β02-Calibration - Backgroundβ (MiR05; 37 Β°C; data recording interval: 2 s; slope smoothi :::: The oxygen sensor test starts in an [[open chamber]].4 KB (638 words) - 14:18, 25 February 2022
- ...2.11 O2k-FluoRespirometer manual]] for calibration of the 2-mL O2k-chamber volume, which is identical for PEEK and PVDF stoppers.386 bytes (56 words) - 14:58, 18 November 2021
- ...tube.com/watch?v=1MSsI1ePMu8&feature=youtu.be O2k-Videosupport: Insert O2k Chamber] .../watch?v=DuaEJc7FBjk&feature=youtu.be O2k-Videosupport: O2k Chamber volume calibration]2 KB (316 words) - 10:04, 29 March 2024
- ...gas phase above the aqueous phase in the 2-mL [[O2k-chamber]], during air calibration or for injection of nitrogen, argon or oxygen into the gas phase; Stopper-S {{Template:Keywords: Chamber volume}}865 bytes (114 words) - 10:33, 11 November 2020
- ...lary and conical basis; including [[Volume-Calibration Ring]] (A or B) for volume adjustment (1.5 to 3.2 mL); 2 mounted O-rings ([[O-ring\Viton\12x1 mm]]).809 bytes (111 words) - 16:27, 14 April 2021
- ...re 2. POS Quality control using the DatLab protocol ([[MiPNet06.03 POS-calibration-SOP]])== ...the oxygen signal (R1) and click on O2 Calib. to open the DatLab O2-Calibration window.6 KB (863 words) - 09:38, 26 June 2020
- ...ollowing entries are entered separately for the left (A) and right (B) O2k-chamber. ...ion about sample used in each chamber. No sample is added in O<sub>2</sub> calibration experiments or upon cleaning.3 KB (481 words) - 13:35, 8 May 2024
- ...trations in the small volume chamber. Here is another test page for the sV-chamber projekt: [[/Digitonin/]] ...centrations updated/]]: these chemical preparation instructions lacked the volume adjustment step4 KB (587 words) - 08:43, 5 April 2022