Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "Smart Fluo-Sensor Blue"

From Bioblast
Β 
(5 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{Product
{{Technical support}}
|description='''Smart Fluo-Sensor Blue''': Excitation LED 465 nm (dominant wavelenght) with short pass filter, emission (red) with long pass filter, individual sensors are calibrated with sensor-specific memory and direct input into DatLab 7 to obtain reproducible light intensities with different sensors, including photodiode, [[Filter-Cap]] equipped with [[Filter Set Saf]] for measurement of mitochondrial membrane potential with [[Safranin|safranin]] and [[Rhodamine 123|rhodamine 123]]. [[Filter Set MgG / CaG]] for [[Magnesium green]] and [[Calcium green]] measurements are included. Β 
__TOC__
{{MitoPedia without banner
|abbr=
|description=[[Image:SmartFluo.png|200px|right]]'''Smart Fluo-Sensor Blue''': Excitation LED 465 nm (dominant wavelenght) with short pass filter, emission (red) with long pass filter, individual sensors are calibrated with sensor-specific memory and direct input into DatLab 7 to obtain reproducible light intensities with different sensors, including photodiode, [[Filter-Cap]] equipped with [[Filter Set Saf]] for measurement of mitochondrial membrane potential with [[Safranin|safranin]] and [[Rhodamine 123|rhodamine 123]]. [[Filter Set MgG / CaG]] for [[Magnesium green]] and [[Calcium green]] measurements are included. Β 
|info=[https://www.oroboros.at/index.php/product/smart-fluo-sensor-blue/ '''Product details and purchase information''']
}}
== Additional resources ==


Two units of this item are standard components of the [[O2k-FluoRespirometer]] and the [[Upgrade of O2k-Respirometer to O2k-FluoRespirometer]]. Smart Fluo-Sensors can be used with O2k-Series H and higher.
:::* [[O2k-Fluo Smart-Module]]
|product id=44222-01
== Troubleshooting ==
|product type=O2k-FluoRespirometer, Power O2k-FluoRespirometer
:::* ''-See'': [[Defective fluorescence module]]
|info=[[Smart Fluo-Sensor]]
{{MitoPedia O2k and high-resolution respirometry
|product image=[[Image:SmartFluo.png|200px|right]]
|mitopedia O2k and high-resolution respirometry=O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry
}}
}}

Latest revision as of 17:14, 16 March 2021


                  


O2k-Open Support

Smart Fluo-Sensor Blue



Template NextGen-O2k.jpg


MitoPedia O2k and high-resolution respirometry: O2k-Open Support 



Description

SmartFluo.png

Smart Fluo-Sensor Blue: Excitation LED 465 nm (dominant wavelenght) with short pass filter, emission (red) with long pass filter, individual sensors are calibrated with sensor-specific memory and direct input into DatLab 7 to obtain reproducible light intensities with different sensors, including photodiode, Filter-Cap equipped with Filter Set Saf for measurement of mitochondrial membrane potential with safranin and rhodamine 123. Filter Set MgG / CaG for Magnesium green and Calcium green measurements are included.


Reference: Product details and purchase information

Additional resources

Troubleshooting

MitoPedia O2k and high-resolution respirometry: O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry