Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "Oxygen flux - instrumental background"

From Bioblast
(added link)
Line 1: Line 1:
{{MitoPedia
{{MitoPedia
|abbr=J°O2
|abbr=''J''°<sub>O2</sub>
|description='''Instrumental background oxygen flux (J°O2)''', in a respirometer is due to oxygen consumption by the [[POS]], and oxygen diffusion into or out of the aqueous medium in the [[O2k-chamber]].  It is measured in the range of experimental oxygen levels by a standardized [[instrumental background test]], and is a property of the instrumental system.  Instrumental background correction eliminates errors by systemic flux compensation, automatically performed by [[DatLab 4.3|DatLab]]. See also [[Chemical background correction of oxygen flux]].
|description='''Instrumental background oxygen flux (''J''°<sub>O2</sub>)''', in a respirometer is due to oxygen consumption by the [[POS]], and oxygen diffusion into or out of the aqueous medium in the [[O2k-chamber]].  It is measured in the range of experimental oxygen levels by a standardized [[instrumental background test]], and is a property of the instrumental system.  Instrumental background correction eliminates errors by systemic flux compensation, automatically performed by [[DatLab 4.3|DatLab]]. See also [[Chemical background correction of oxygen flux]].
|info=[[MiPNet14.06]]; [[Gnaiger_2008_POS]]; [[Gnaiger_2001_RespPhysiol]]
|info=[[MiPNet14.06]]; [[Gnaiger_2008_POS]]; [[Gnaiger_2001_RespPhysiol]]
|type=Respiration
|type=Respiration
}}
}}
{{Labeling
{{Labeling
|topics=Respiration; OXPHOS; ETS Capacity
|instruments=Oxygraph-2k, DatLab Software; Separate Application, Method
|instruments=Oxygraph-2k, DatLab Software; Separate Application, Method
|topics=Respiration; OXPHOS; ETS Capacity
|type=Respiration
}}
}}

Revision as of 14:27, 21 October 2010


high-resolution terminology - matching measurements at high-resolution


Oxygen flux - instrumental background

Description

Instrumental background oxygen flux (J°O2), in a respirometer is due to oxygen consumption by the POS, and oxygen diffusion into or out of the aqueous medium in the O2k-chamber. It is measured in the range of experimental oxygen levels by a standardized instrumental background test, and is a property of the instrumental system. Instrumental background correction eliminates errors by systemic flux compensation, automatically performed by DatLab. See also Chemical background correction of oxygen flux.

Abbreviation: J°O2

Reference: MiPNet14.06; Gnaiger_2008_POS; Gnaiger_2001_RespPhysiol


Labels:




Regulation: Respiration; OXPHOS; ETS Capacity"Respiration; OXPHOS; ETS Capacity" is not in the list (Aerobic glycolysis, ADP, ATP, ATP production, AMP, Calcium, Coupling efficiency;uncoupling, Cyt c, Flux control, Inhibitor, ...) of allowed values for the "Respiration and regulation" property. 


HRR: Oxygraph-2k, DatLab Software; Separate Application"DatLab Software; Separate Application" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property., Method"Method" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property.