Description
Non-coupled respiration is distinguished from general (pharmacological or mechanical) uncoupled respiration, to give a label to an effort to reach the fully uncoupled (non-coupled) state without inhibiting respiration. Non-coupled respiration, therefore, yields an estimate of ETS capacity. Experimentally uncoupled respiration may fail to yield an estimate of ETS capacity, due to inhibition of respiration above optimum uncoupler concentrations or insufficient stimulation by sub-optimal uncoupler concentrations. Optimum uncoupler concentrations for evaluation of (non-coupled) ETS capacity require inhibitor titrations (Steinlechner-Maran_1996_AJP; Huetter_2004_BJ; Gnaiger_2008_POS).
Non-coupled respiration is maximum electron flow in an open-transmembrane proton circuit mode of operation (see ETS capacity).
Abbreviation: E
Reference: Gnaiger 2012 MitoPathways, MitoPedia Glossary: Respiratory states
MitoPedia methods:
Respirometry
MitoPedia topics: "Respiratory state" is not in the list (Enzyme, Medium, Inhibitor, Substrate and metabolite, Uncoupler, Sample preparation, Permeabilization agent, EAGLE, MitoGlobal Organizations, MitoGlobal Centres, ...) of allowed values for the "MitoPedia topic" property.
Respiratory state"Respiratory state" is not in the list (Enzyme, Medium, Inhibitor, Substrate and metabolite, Uncoupler, Sample preparation, Permeabilization agent, EAGLE, MitoGlobal Organizations, MitoGlobal Centres, ...) of allowed values for the "MitoPedia topic" property.
- Why non-coupled versus uncoupled? - Talk:Uncoupled respiration