Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "Park 2007 Sensors IEEE"

From Bioblast
Β 
(11 intermediate revisions by 4 users not shown)
Line 1: Line 1:
{{Publication
{{Publication
|title=Park J, Chang J, Choi M, Pak JJ, DY Lee, Pak YK (2007) Microfabricated Clark-type sensor for measuring dissolved oxygen. Sensors IEEE: 1412-1415.
|title=Park J, Chang J, Choi M, Pak JJ, Lee DY, Pak YK (2007) Microfabricated Clark-type sensor for measuring dissolved oxygen. Sensors IEEE: 1412-1415.
|info=[http://ieeexplore.ieee.org/xpl/freeabs_all.jsp?arnumber=4388677 IEEE ]
|info=[http://ieeexplore.ieee.org/xpl/freeabs_all.jsp?arnumber=4388677 IEEE ]
|authors=Park J, Chang J, Choi M, Pak JJ, DY Lee, Pak YK
|authors=Park J, Chang J, Choi M, Pak JJ, Lee DY, Pak YK
|year=2007
|year=2007
|journal=IEEE
|journal=IEEE
Line 11: Line 11:
}}
}}
{{Labeling
{{Labeling
|area=Respiration, Instruments;methods
|instruments=Oxygraph-2k
|instruments=Oxygraph-2k
|organism=Other Mammal
|additional=KR,
|topics=Respiration; OXPHOS; ETS Capacity
|discipline=Biomedicine
|discipline=Biomedicine
|articletype=Protocol; Manual
|articletype=Protocol; Manual
}}
}}

Latest revision as of 17:25, 25 February 2020

Publications in the MiPMap
Park J, Chang J, Choi M, Pak JJ, Lee DY, Pak YK (2007) Microfabricated Clark-type sensor for measuring dissolved oxygen. Sensors IEEE: 1412-1415.

Β» IEEE

Park J, Chang J, Choi M, Pak JJ, Lee DY, Pak YK (2007) IEEE

Abstract: This paper presents a microfabricated Clark-type sensor which exactly can measure dissolved oxygen in the cell containing solution. We designed and fabricated a microfabricated Clark-type sensor for measuring the oxygen respiration level of few cells. The microfabricated Clark-type sensor is composed of 3-electrodes on a glass substrate, a FEP (Fluorinated ethylene propylene) oxygen-permeable membrane, and PDMS (Polydimethylsiloxane) reservoir for storing few cells containing solution. The microfabricated Clark-type sensor was fabricated using MEMS technology. Thin-film Ag/AgCl was employed as a reference electrode and its durability was verified by obtaining a stable open circuit potential versus a commercial Ag/AgCl electrode for 2 hours. Response time, reproducibility and linearity of the fabricated oxygen sensor were examined by amperometry. The fabricated Clark-type sensor showed 40 sec of 90% response time, reproducibility with 1.37 nA standard deviation of 97.03 nA mean in the full-oxygen state and 0.26 nA standard deviation of 3.25 nA mean in the zero-oxygen state, and an excellent linearity with a correlation coefficient of 0.994.


β€’ O2k-Network Lab: KR_Seoul_Pak YK


Labels: MiParea: Respiration, Instruments;methods 





HRR: Oxygraph-2k 

KR