{{MitoPedia
#REDIRECT [[OroboPOS-Holder]]
|description=
The OroboPOS-Holder (POS-Holder), made from blue POM, is screwed into the copper block of the O2k-Main Unit, guiding the OroboPOS-Connector with the OroboPOS sensor head (POS) to the O2k-Chamber, and keeping the OroboPOS-Connector in a fixed position for sealing the O2k-Chamber with the OroboPOS-Seal Tip. In addition, the OroboPOS-Holder fixes the O2k-Chamber in an accurate rotational position by pressing against the angular cut of the glass chamber.
Β 
Two units of this item are standard components mounted on the O2k-Main Unit.
|info=[[OroboPOS-Holder]]
}}
Β 
{{MitoPedia O2k and high-resolution respirometry
|mitopedia O2k and high-resolution respirometry=O2k hardware
}}
Β 
__TOC__
Β 
{{Template:Technical support integrated}}
Β 
== O2k-OroboPOS-Holder: Leaky chamber due to damaged OroboPOS-Holder==
Β 
:::* In order not to experience a leakage after chamber reassembly, make sure that all the parts are in good conditions, especially the OroboPOS-Holder
:::* The OroboPOS-Holder may experience some damage due to the not proper alignment with the thread
:::* The OroboPOS-Holder may experience some damage due to the not proper alignment with the chamber
:::* The OroboPOS-Holder may experience some damage due to frequent and bad performed mounting and dismounting procedures
Β 
:::* In case your OroboPOS-Holder already presents dents on the surfaces ( see pictures below) you may experience leakage, sanding the edge of the OroboPOS-Holder with sand paper may solve the issue.
Β 
[[File:OroboPOS-Holder002.jpg|left|200px]]
[[File:OroboPOS-Holder003.jpg|right|200px]]
[[File:OroboPOS-Holder004.jpg|centre|200px]]
Β 
* Left picture: brand new OroboPOS-Holder, no damage on the thred, no damage on the edge
* Center picture: used OroboPOS-Holder, almost no damage on the thred, the edge is slightly damaged
* Right picture: heavly used OroboPOS-Holder, the thred is slightly damaged, serious damage on the edge of the aperture
Β 
:::* For more information, please see: [https://www.youtube.com/watch?v=1MSsI1ePMu8&feature=youtu.be Chamber service Insert O2k Chamber]
Β 
{{MitoPedia concepts}}
{{MitoPedia methods}}
{{MitoPedia O2k and high-resolution respirometry}}
{{MitoPedia topics}}
{{MitoPedia O2k and high-resolution respirometry
|mitopedia O2k and high-resolution respirometry=O2k hardware
}}

Latest revision as of 18:05, 10 November 2020

Redirect to: