Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "NS-N pathway control efficiency"

From Bioblast
Line 1: Line 1:
{{MitoPedia
{{MitoPedia
|abbr=''j''<sub>CI&II-CI</sub>
|abbr=''j''<sub>CI<small>&</small>II-CI</sub>
|description=The '''CI&II-CI [[substrate control factor]]''' expresses the fractional change of flux when succinate is added to [[CI-linked respiration]] in a defined [[coupling control state]]. The symbol '&' in CI&II helps to distinguish CI&II as the measured flux in the presence of both CI- '''and''' CII-linked substrates from CI+CII as the operation of a mathematical addition when calculating the sum of CI- plus CII-linked respiration measured separately.
|description=The '''CI<small>&</small>II-CI [[substrate control factor]]''', ''j''<sub>CI<small>&</small>II-CI</sub> = 1-CI/CI<small>&</small>II,Β  expresses the fractional change of flux when succinate is added to [[CI-linked respiration]] in a defined [[coupling control state]]. The symbol '&' in CI<small>&</small>II helps to distinguish CI<small>&</small>II as the measured flux in the presence of both CI- '''and''' CII-linked substrates from CI+CII as the operation of a mathematical addition when calculating the sum of CI- plus CII-linked respiration measured separately.
|info=[[Flux control factor]]
|info=[[Flux control factor]]
}}
}}

Revision as of 12:49, 3 October 2015


high-resolution terminology - matching measurements at high-resolution


NS-N pathway control efficiency

Description

The CI&II-CI substrate control factor, jCI&II-CI = 1-CI/CI&II, expresses the fractional change of flux when succinate is added to CI-linked respiration in a defined coupling control state. The symbol '&' in CI&II helps to distinguish CI&II as the measured flux in the presence of both CI- and CII-linked substrates from CI+CII as the operation of a mathematical addition when calculating the sum of CI- plus CII-linked respiration measured separately.

Abbreviation: jCI&II-CI

Reference: Flux control factor


MitoPedia methods: Respirometry 


MitoPedia topics: "Respiratory control ratio" is not in the list (Enzyme, Medium, Inhibitor, Substrate and metabolite, Uncoupler, Sample preparation, Permeabilization agent, EAGLE, MitoGlobal Organizations, MitoGlobal Centres, ...) of allowed values for the "MitoPedia topic" property. Respiratory control ratio"Respiratory control ratio" is not in the list (Enzyme, Medium, Inhibitor, Substrate and metabolite, Uncoupler, Sample preparation, Permeabilization agent, EAGLE, MitoGlobal Organizations, MitoGlobal Centres, ...) of allowed values for the "MitoPedia topic" property. 

Compare