Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "MiPNet25.03 IOC144 Innsbruck AT"

From Bioblast
Line 68: Line 68:
|ORO-MitoFit Lab
|ORO-MitoFit Lab
|-
|-
|09:30
|09:15
|'''Hands-on''': OroboPOS service and O2k instrumental setup Β 
|'''Hands-on''': OroboPOS service and O2k instrumental setup Β 
|ORO-MitoFit Lab
|ORO-MitoFit Lab
|-
|-
|10:10
|09:55
|'''Hands-on''': DatLab 7 Β 
|DatLab 7.4 overview
|ORO-MitoFit Lab
|ORO-MitoFit Lab
|-
|-
Line 87: Line 87:
|'''Hands-on''': Instrumental quality control 1: oxygen calibration
|'''Hands-on''': Instrumental quality control 1: oxygen calibration


DL-Protocol: O2k-cleaning before use
DL-Protocol: O2k-cleaning BeforeUse


DL-Protocol: O2 calibration air
DL-Protocol: O2 calibration air
Line 97: Line 97:
|-
|-
|13:00
|13:00
|'''Hands-on''':Instrumental quality control 1: oxygen calibration (continuation)
|'''Hands-on''': Instrumental quality control 1: oxygen calibration (continuation)
DL-Protocol: O2 calibration air Β 
DL-Protocol: O2 calibration air Β 
|ORO-MitoFit Lab
|ORO-MitoFit Lab
|-
|-
|13:30
|13:30
|Instrumental quality control 2: Instrumental O2 background – overview with videoclips
|Instrumental quality control 2: Instrumental O<sub>2</sub> background – overview with videoclips
|ORO-MitoFit Lab
|ORO-MitoFit Lab
|-
|-
|14:00
|14:00
|'''Hands-on''':Instrumental quality control 2: Instrumental O2 background Β 
|'''Hands-on''':Instrumental quality control 2: Instrumental O<sub>2</sub> background Β 
DL-Protocol: Instrumental O2 background TiP2k
DL-Protocol: Instrumental O2 background TiP2k
|ORO-MitoFit Lab
|ORO-MitoFit Lab
Line 114: Line 114:
|
|
|-
|-
|15:30-18:00
|15:30-17:30
|'''Hands-on''': Instrumental quality control 1 and 2. DatLab analysis.
|'''Hands-on''': Instrumental quality control 1 and 2. DatLab analysis.
|ORO-MitoFit Lab
|ORO-MitoFit Lab
Line 134: Line 134:
|style="width: 15em"|'''Room'''
|style="width: 15em"|'''Room'''
|-
|-
|09:00
|08:30
|Hands-on: Instrumental quality control 1: oxygen calibration
|Hands-on: Instrumental quality control 1: oxygen calibration


DL-Protocol: O2k-cleaning before use
DL-Protocol: O2k-cleaning BeforeUse


DL-Protocol: O2 calibration air
DL-Protocol: O2 calibration air
Line 143: Line 143:
|-
|-
|09:15
|09:15
|Application of the O2k Series HΒ 
|Introduction to substrate-uncoupler-inhibitor titration (SUIT) protocols – fundamental principles. SUIT reference protocol: RP1&RP2
|ORO-MitoFit Lab
|ORO-MitoFit Lab
|-
|-
|09:30
|09:45
|Introduction to substrate-uncoupler-inhibitor titration (SUIT) protocols – fundamental principles. SUIT reference protocol: RP1&RP2
|SUITbrowser: how to find the best SUIT protocol for your research questions. Β 
|ORO-MitoFit Lab
|ORO-MitoFit Lab
|-
|-
Line 155: Line 155:
|-
|-
|10:30
|10:30
|'''Hands-on''': O2k-Demo experiment: Respiration of permeabilized cells: measurement of oxygen consumption with RP1 and RP2. Β 
|'''Hands-on''': O2k-Demo experiment: Respiration of permeabilized cells: measurement of oxygen consumption with the reference protocol RP1 (SUIT-001) and RP2 (SUIT-002). Β 


DL-Protocol: SUIT-1_O2_pce_D03.DLP
DL-Protocol: SUIT-001 O2 ce-pce D003.DLP Β 


DL-Protocol: SUIT-2 O2 pce D07.DLP
DL-Protocol: SUIT-002 O2 ce-pce D007.DLP


|ORO-MitoFit Lab
|ORO-MitoFit Lab
Line 166: Line 166:
|'''Hands-on''': O2k-cleaning after use
|'''Hands-on''': O2k-cleaning after use


DL-Protocol: O2k-cleaning after use
DL-Protocol: O2k-cleaning AfterUse
|ORO-MitoFit Lab
|ORO-MitoFit Lab
|-
|-
Line 174: Line 174:
|-
|-
|13:00
|13:00
|'''Hands-on''': O2k-cleaning after use
|'''Hands-on''': O2k-cleaning after use (continuation)


DL-Protocol: O2k-cleaning after use
DL-Protocol: O2k-cleaning AfterUse
|ORO-MitoFit Lab
|ORO-MitoFit Lab
|-
|-
|13:30
|13:30
|Introduction to DatLab analysis
|DatLab 7.4 analysis: Introduction and new features
|ORO-MitoFit Lab
|ORO-MitoFit Lab
|-
|-
Line 187: Line 187:
|
|
|-
|-
|15:30-18:00
|15:30-17:30
|Individual DatLab analysis + summary
|Individual DatLab analysis + summary
|ORO-MitoFit Lab
|ORO-MitoFit Lab
Line 206: Line 206:
|style="width: 15em"|'''Room'''
|style="width: 15em"|'''Room'''
|-
|-
|09:00
|08:30
|'''MitoFit proficiency test:'''
|'''MitoFit proficiency test'''


'''Hands-on''': Instrumental quality control 1: oxygen calibration
'''Hands-on''': Instrumental quality control 1: oxygen calibration


DL-Protocol: O2k-cleaning before use
DL-Protocol: O2k-cleaning BeforeUse


DL-Protocol: O2 calibration air
DL-Protocol: O2 calibration air
Line 224: Line 224:
|'''MitoFit proficiency test:'''
|'''MitoFit proficiency test:'''


'''Hands-on''': O2k-Demo experiment: Respiration of permeabilized cells: measurement of oxygen consumption with RP1 and RP2. Β 
'''Hands-on''': O2k-Demo experiment: Respiration of permeabilized cells: measurement of oxygen consumption with the reference protocol RP1 (SUIT-001) and RP2 (SUIT-002).


DL-Protocol: SUIT-1_O2_pce_D03.DLP
DL-Protocol: SUIT-001 O2 ce-pce D003.DLP Β 


DL-Protocol: SUIT-2 O2 pce D07.DLP
DL-Protocol: SUIT-002 O2 ce-pce D007.DLP Β 


|ORO-MitoFit Lab
|ORO-MitoFit Lab
Line 235: Line 235:
|'''Hands-on''': O2k-cleaning after use
|'''Hands-on''': O2k-cleaning after use


DL-Protocol: O2k-cleaning after use
DL-Protocol: O2k-cleaning AfterUse
|ORO-MitoFit Lab
|ORO-MitoFit Lab
|-
|-
Line 243: Line 243:
|-
|-
|13:00
|13:00
|'''Hands-on''': O2k-cleaning after use
|'''Hands-on''': O2k-cleaning after use (continuation)


DL-Protocol: O2k-cleaning after use
DL-Protocol: O2k-cleaning AfterUse
|ORO-MitoFit Lab
|ORO-MitoFit Lab
|-
|-
Line 253: Line 253:
|-
|-
|14:00
|14:00
|DatLab analysis summary
|O2k-Applications - overview
|ORO-MitoFit Lab
|-
|14:30
|Proficiency test: DatLab analysis summary
|ORO-MitoFit Lab
|ORO-MitoFit Lab
|-
|-
Line 261: Line 265:
|-
|-
|15:30
|15:30
|The Bioblast wiki, O2k-Network and MITOEAGLE
|The Bioblast wiki, MitoFit Preprint Archives, O2k-Network and MitoEAGLE
|MiP''Art''
|MiP''Art''
|-
|-
|16:15
|16:30
|Feedback & conclusions Β 
|Feedback & conclusions Β 
|MiP''Art''
|MiP''Art''

Revision as of 10:42, 6 November 2019

                



MiPNet25.03 IOC144 Innsbruck AT


Publications in the MiPMap
OROBOROS-solo.png

Innsbruck AT, 2020 Jan 20-22. MitoFit Coaching Days - Basic IOC144.


Oroboros (2020-01-20) Mitochondr Physiol Network

Abstract:

O2k-Workshops.png

MitoFit Coaching Days - Basic. Innsbruck, Austria; 2020 Jan 20-22.


β€’ O2k-Network Lab: AT_Innsbruck_Oroboros, AT_Innsbruck_MitoFit

Template NextGen-O2k.jpg


General information

MitoFit Coaching Days - Basic is a training course which provides a fundamental introduction to high-resolution respirometry (HRR) with the Oroboros O2k. We will give you an overview of the O2k-FluoRespirometer, including real-time analysis with DatLab 7.4 and applications of the Titration-Injection microPump TIP2k. Hands-on sessions range from OroboPOS technical service (instrumental quality control system which is an essential component of HRR) to respirometry experiments with substrate-uncoupler-inhibitor (SUIT) protocols. Also the new Oroboros SUITbrowser will be presented. The SUITbrowser helps you to find the best SUIT protocol for your specific research questions. Many optimized SUIT protocols are available as DL-Protocols and will be shown at the Coaching Days.


Venue

Β» Oroboros MitoFit Laboratory
Schoepfstrasse 18, 6020 Innsbruck
Β» Information on travel and venue: IOC Innsbruck.
Β» Hotel recommendation: Basic Hotel Innsbruck***(https://www.basic-hotel.at/en/)
Using code "OROBOROS" for booking online you will get the Single Room for € 85.00 and the Double Room for € 120.00 including breakfast. Rooms are available at a first come first served basis.
Free cancellation until 7 days prior. Booking requires a credit card for guarantee. Payment on site. A 2€ City tax to be charged additionally.

Registration


Download registration form, fill in the pdf and then print to sign: download pdf


Tutors and lecturers


Preliminary programme


Monday 20th

Topic Room
08:15 Welcome - Get-together: Introduction of participants and their research interests ORO-MitoFit Lab
08:30 OroboPOS service and O2k instrumental setup - overview with videoclips ORO-MitoFit Lab
09:15 Hands-on: OroboPOS service and O2k instrumental setup ORO-MitoFit Lab
09:55 DatLab 7.4 overview ORO-MitoFit Lab
10:30 Coffee
11:00 Instrumental quality control 1: oxygen calibration ORO-MitoFit Lab
11:30 Hands-on: Instrumental quality control 1: oxygen calibration

DL-Protocol: O2k-cleaning BeforeUse

DL-Protocol: O2 calibration air

ORO-MitoFit Lab
12:00 Lunch break
13:00 Hands-on: Instrumental quality control 1: oxygen calibration (continuation)

DL-Protocol: O2 calibration air

ORO-MitoFit Lab
13:30 Instrumental quality control 2: Instrumental O2 background – overview with videoclips ORO-MitoFit Lab
14:00 Hands-on:Instrumental quality control 2: Instrumental O2 background

DL-Protocol: Instrumental O2 background TiP2k

ORO-MitoFit Lab
15:00 Coffee
15:30-17:30 Hands-on: Instrumental quality control 1 and 2. DatLab analysis. ORO-MitoFit Lab


Tuesday 21st

Topic Room
08:30 Hands-on: Instrumental quality control 1: oxygen calibration

DL-Protocol: O2k-cleaning BeforeUse

DL-Protocol: O2 calibration air

ORO-MitoFit Lab
09:15 Introduction to substrate-uncoupler-inhibitor titration (SUIT) protocols – fundamental principles. SUIT reference protocol: RP1&RP2 ORO-MitoFit Lab
09:45 SUITbrowser: how to find the best SUIT protocol for your research questions. ORO-MitoFit Lab
10:00 Coffee
10:30 Hands-on: O2k-Demo experiment: Respiration of permeabilized cells: measurement of oxygen consumption with the reference protocol RP1 (SUIT-001) and RP2 (SUIT-002).

DL-Protocol: SUIT-001 O2 ce-pce D003.DLP

DL-Protocol: SUIT-002 O2 ce-pce D007.DLP

ORO-MitoFit Lab
11:45 Hands-on: O2k-cleaning after use

DL-Protocol: O2k-cleaning AfterUse

ORO-MitoFit Lab
12:00 Lunch break
13:00 Hands-on: O2k-cleaning after use (continuation)

DL-Protocol: O2k-cleaning AfterUse

ORO-MitoFit Lab
13:30 DatLab 7.4 analysis: Introduction and new features ORO-MitoFit Lab
15:00 Coffee
15:30-17:30 Individual DatLab analysis + summary ORO-MitoFit Lab


Wednesday 22nd

Topic Room
08:30 MitoFit proficiency test

Hands-on: Instrumental quality control 1: oxygen calibration

DL-Protocol: O2k-cleaning BeforeUse

DL-Protocol: O2 calibration air

ORO-MitoFit Lab
10:00 Coffee
10:30 MitoFit proficiency test:

Hands-on: O2k-Demo experiment: Respiration of permeabilized cells: measurement of oxygen consumption with the reference protocol RP1 (SUIT-001) and RP2 (SUIT-002).

DL-Protocol: SUIT-001 O2 ce-pce D003.DLP

DL-Protocol: SUIT-002 O2 ce-pce D007.DLP

ORO-MitoFit Lab
11:45 Hands-on: O2k-cleaning after use

DL-Protocol: O2k-cleaning AfterUse

ORO-MitoFit Lab
12:00 Lunch break
13:00 Hands-on: O2k-cleaning after use (continuation)

DL-Protocol: O2k-cleaning AfterUse

ORO-MitoFit Lab
13:15 DatLab analysis ORO-MitoFit Lab
14:00 O2k-Applications - overview ORO-MitoFit Lab
14:30 Proficiency test: DatLab analysis summary ORO-MitoFit Lab
15:00 Coffee
15:30 The Bioblast wiki, MitoFit Preprint Archives, O2k-Network and MitoEAGLE MiPArt
16:30 Feedback & conclusions MiPArt
17:00 Farewell activity MiPArt

Participants

Participant Institution
Participant Buoso Chiara AT Innsbruck Weiss G - Medical University Innsbruck, Innsbruck (AT)
Kate Griffiths Griffiths Kate UK Glasgow Selman C - Glasgow University, Glasgow (UK)

Contact

Oroboros Instruments GmbH
High-Resolution Respirometry
Schoepfstrasse 18
A-6020 Innsbruck, Austria
Tel: +43 512 566796
Fax: +43 512 566796 20
E-Mail: [email protected]
Mitochondria and Cell Research


IOC recommended reading

Β» IOC recommended reading
Β» MitoPedia: Respiratory states
OXPHOS ROUTINE ETS LEAK ROX


MitoGlobal
O2k-Workshops and MitoFit Coaching Days are listed as MitoGlobal Events.


Labels:






ORO, IOC, MitoGlobal, Next, 2020