Difference between revisions of "MiPNet24.14 O2k-sV-Module manual"

From Bioblast
Jump to: navigation, search
Line 15: Line 15:
 
|mipnetlab=AT_Innsbruck_Oroboros
 
|mipnetlab=AT_Innsbruck_Oroboros
 
}}
 
}}
 +
{{MitoPedia without banner
 +
|abbr=O2k-sV-Module
 +
|description=The '''O2k-sV-Module''' consists of two 0.5 mL glass chambers and accessories for insertion into the O2k, for respiratory measurements with small amounts of sample, providing flexibility in addition to the standard 2 mL chamber.
 +
|info=
 +
}}
 +
__TOC__
 +
{{Technical support integrated}}
 +
 
{{Labeling
 
{{Labeling
 
|area=Instruments;methods
 
|area=Instruments;methods
Line 20: Line 28:
 
|additional=DatLab,
 
|additional=DatLab,
 
}}
 
}}
 
 
 
 
 
 
 
{{Technical support integrated}}
 

Revision as of 14:25, 7 November 2019

Oroboros Instruments

News         O2k-Products         O2k-Purchase         O2k-Open Support         O2k-Publications         O2k-Workshops and Events         O2k-Network         O2k-Feedback         NextGen-O2k



MiPNet24.14 O2k-sV-Module manual


Publications in the MiPMap
O2k-Manual
O2k-sV-Module manual.

» Bioblast pdf »Versions

Oroboros (2019-10-23) Mitochondr Physiol Network

Abstract: Passrugger M, Gallée L, Krumschnabel G, Tindle-Solomon L, Gnaiger E, Doerrier C (2019) O2k-sV-Module manual. Mitochondr Physiol Network 24.14(01):1-8.

O2k-Manual: The O2k-sV-Module is a modular extension of the O2k specifically designed to perform high-resolution respirometry with reduced amount of biological sample and chemicals, leading to an overall decrease of running costs and expanding the application scope of samples with limited availability. The O2k-sV-Module exchanges the standard 2 mL O2k-Chamber for a smaller operation volume of 0.5 mL. The O2k-sV-Module is compatible with all O2k-Series, however it cannot be used for simultaneous measurement of multiple parameters in the O2k-FluoRespirometer or in combination with the O2k-MultiSensor Modules. The use of O2k-sV-Module is recommended at normoxic range, in a narrow experimental range of oxygen concentration near air saturation to reduce technical problems of oxygen diffusion and instrumental O2 background.

» Product:O2k-sV-Module, Oroboros O2k-Catalogue


O2k-Network Lab: AT_Innsbruck_Oroboros


Description

The O2k-sV-Module consists of two 0.5 mL glass chambers and accessories for insertion into the O2k, for respiratory measurements with small amounts of sample, providing flexibility in addition to the standard 2 mL chamber.

Abbreviation: O2k-sV-Module

Contents

Template NextGen-O2k.jpg
O2k-Open Support


MitoPedia O2k and high-resolution respirometry: O2k-Open Support 


Labels: MiParea: Instruments;methods 





HRR: Oxygraph-2k, O2k-Fluorometer, O2k-Manual 

DatLab