Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "MiPNet20.14 AmplexRed H2O2-production"

From Bioblast
Line 12: Line 12:
|organism=Mouse
|organism=Mouse
|tissues=Heart
|tissues=Heart
|preparations=Isolated Mitochondria
|preparations=Isolated mitochondria
|couplingstates=LEAK, OXPHOS, ETS
|couplingstates=LEAK, OXPHOS, ETS
|substratestates=CII
|substratestates=CII
|instruments=Oxygraph-2k, Fluorometry, Protocol
|instruments=Oxygraph-2k, O2k-Fluorometer, Protocol
}}
}}
== Reference ==
== Reference ==
Krumschnabel G, Fontana-Ayoub M, Sumbalova Z, Heidler J, Gauper K, Fasching M, Gnaiger E  (2015) Simultaneous high-resolution measurement of mitochondrial respiration and hydrogen peroxide production. Methods Mol Biol 1264:245-61. » [[Krumschnabel_2015_Methods_Mol_Biol]]
Krumschnabel G, Fontana-Ayoub M, Sumbalova Z, Heidler J, Gauper K, Fasching M, Gnaiger E  (2015) Simultaneous high-resolution measurement of mitochondrial respiration and hydrogen peroxide production. Methods Mol Biol 1264:245-61. » [[Krumschnabel_2015_Methods_Mol_Biol]]

Revision as of 14:57, 13 February 2015

Publications in the MiPMap
O2k-Protocols
Amplex Red data acquisition and analysis (2014) O2k-Fluorometry: HRR and simultaneous determination of H2O2 production with Amplex Red.

» Open Access-MiPNet19.20.pdf; Versions

OROBOROS (2014-10) Mitochondr Physiol Network

Abstract: Krumschnabel G, Makrecka-Kuka M, Kumphune S, Fontana-Ayoub M, Fasching M, Gnaiger E (2014) O2k-Fluorometry: HRR and simultaneous determination of H2O2 production with Amplex Red. Mitochondr Physiol Network 19.20(01): 1-6.


O2k-Network Lab: AT_Innsbruck_OROBOROS


Labels: MiParea: Respiration, Instruments;methods 


Organism: Mouse  Tissue;cell: Heart  Preparation: Isolated mitochondria 


Coupling state: LEAK, OXPHOS, ETS"ETS" is not in the list (LEAK, ROUTINE, OXPHOS, ET) of allowed values for the "Coupling states" property. 

HRR: Oxygraph-2k, O2k-Fluorometer, Protocol"Protocol" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property. 


Reference

Krumschnabel G, Fontana-Ayoub M, Sumbalova Z, Heidler J, Gauper K, Fasching M, Gnaiger E (2015) Simultaneous high-resolution measurement of mitochondrial respiration and hydrogen peroxide production. Methods Mol Biol 1264:245-61. » Krumschnabel_2015_Methods_Mol_Biol