|title= | |title=Fasching M (2012) O2k-Fluorometry - A MitoCom Project. Mitochondr Physiol Network 17.17. | ||
|info=[http://www.oroboros.at/index.php?id=o2k- | |info=[http://www.oroboros.at/index.php?id=o2k-fluorescenceled2-module MiPNet17.17] | ||
|authors= | |authors=Fasching M, Sumbalova Z, Gnaiger E | ||
|year=2012 | |year=2012 | ||
|journal=Mitochondr Physiol Network | |journal=Mitochondr Physiol Network | ||
|abstract= | |abstract=High-resolution respirometry [1] is extended by MultiSensor techniques allowing the simultaneous measurement of oxygen consumption and one additional parameter (mitochondrial membrane potential, pH, Ca2+, or NO concentration [2, 3]). Fluorometric methods are available for a wide range of analytical parameters of major interest in mitochochondrial physiology: H2O2 production, mitochondrial membrane potential, intracellular pH, Ca2+, Mg2+ , and NADH levels. | ||
|keywords=Oxygraph-2k, High-resolution respirometry, | Advantages of the simultaneous measurement of additional parameters in a single respirometric chamber: | ||
# Quality control of preparations by respirometric performance. | |||
# Objective exclusion criteria for protocol related problems, e.g. overtitration of uncouplers, side effects of TPP+ or fluorophores. | |||
# Elimination of artifacts of normalization for a mitochondrial marker when combining two methods in a single chamber. | |||
# Additional information is acquired for a limited amount of sample. | |||
# Oxygen dependence of parameters can be studied. | |||
Here we introduce the O2k-Fluorescence LED2-Module, describe one selected stage in its development, and show its application for the simultaneous measurement of respiration and H2O2 production of mouse brain mitochondria. | |||
|keywords=Oxygraph-2k, High-resolution respirometry, Spectrofluorometry, MitoCom | |||
|mipnetlab=AT_Innsbruck_OROBOROS | |mipnetlab=AT_Innsbruck_OROBOROS | ||
|articletype=Workshop, MiPNet-online Publication | |articletype=Workshop, MiPNet-online Publication | ||
}} | }} | ||
{{Labeling | {{Labeling | ||
|instruments=Oxygraph-2k, | |instruments=Oxygraph-2k, Spectrofluorimetry, MiPNet-Publication | ||
|articletype=Workshop, MiPNet-online Publication | |articletype=Workshop, MiPNet-online Publication | ||
}} | }} |
Revision as of 16:44, 10 January 2013
Fasching M (2012) O2k-Fluorometry - A MitoCom Project. Mitochondr Physiol Network 17.17. |
Β» MiPNet17.17
Fasching M, Sumbalova Z, Gnaiger E (2012) Mitochondr Physiol Network
Abstract: High-resolution respirometry [1] is extended by MultiSensor techniques allowing the simultaneous measurement of oxygen consumption and one additional parameter (mitochondrial membrane potential, pH, Ca2+, or NO concentration [2, 3]). Fluorometric methods are available for a wide range of analytical parameters of major interest in mitochochondrial physiology: H2O2 production, mitochondrial membrane potential, intracellular pH, Ca2+, Mg2+ , and NADH levels. Advantages of the simultaneous measurement of additional parameters in a single respirometric chamber:
- Quality control of preparations by respirometric performance.
- Objective exclusion criteria for protocol related problems, e.g. overtitration of uncouplers, side effects of TPP+ or fluorophores.
- Elimination of artifacts of normalization for a mitochondrial marker when combining two methods in a single chamber.
- Additional information is acquired for a limited amount of sample.
- Oxygen dependence of parameters can be studied.
Here we introduce the O2k-Fluorescence LED2-Module, describe one selected stage in its development, and show its application for the simultaneous measurement of respiration and H2O2 production of mouse brain mitochondria. β’ Keywords: Oxygraph-2k, High-resolution respirometry, Spectrofluorometry, MitoCom
β’ O2k-Network Lab: AT_Innsbruck_OROBOROS
Labels:
HRR: Oxygraph-2k, Spectrofluorimetry"Spectrofluorimetry" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property., MiPNet-Publication"MiPNet-Publication" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property.