Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "MiPNet17.03 Shredder vs Fibers"

From Bioblast
Line 8: Line 8:


In the present study we compared mitochondrial function of permeabilized fibres and homogenate of heart muscle of mice. In addition, respiration of trout heart homogenate preparations were compared with permeabilized fibres, and the PBI-Shredder was successfully tested with preparation of trout liver.
In the present study we compared mitochondrial function of permeabilized fibres and homogenate of heart muscle of mice. In addition, respiration of trout heart homogenate preparations were compared with permeabilized fibres, and the PBI-Shredder was successfully tested with preparation of trout liver.
:>> Product: [http://www.oroboros.at/?oxygraph OROBOROS O2k], [[O2k-Catalogue_OROBOROS| O2k-Catalogue]]
:>> Product: [http://www.oroboros.at/?oxygraph OROBOROS O2k], [[OROBOROS O2k-Catalogue | O2k-Catalogue]]
|keywords=Tissue homogenate, Shredder
|keywords=Tissue homogenate, Shredder
|mipnetlab=AT_Innsbruck_OROBOROS, AT Innsbruck MitoCom
|mipnetlab=AT_Innsbruck_OROBOROS, AT Innsbruck MitoCom

Revision as of 14:00, 24 June 2015

Publications in the MiPMap
O2k-Protocols
Mitochondrial respiration in permeabilized fibres versus homogenate from fish liver and heart. An application study with the PBI-Shredder. »Bioblast pdf«

» Versions

OROBOROS (2015-06-18) Mitochondr Physiol Network

Abstract: Doerrier C, Draxl A, Wiethuechter A, Eigentler A, Gnaiger E (2015) Mitochondrial respiration in permeabilized fibres versus homogenate from fish liver and heart. An application study with the PBI-Shredder. Mitochondr Physiol Network 17.03(04):1-9.

In the present study we compared mitochondrial function of permeabilized fibres and homogenate of heart muscle of mice. In addition, respiration of trout heart homogenate preparations were compared with permeabilized fibres, and the PBI-Shredder was successfully tested with preparation of trout liver.

>> Product: OROBOROS O2k, O2k-Catalogue

Keywords: Tissue homogenate, Shredder

O2k-Network Lab: AT_Innsbruck_OROBOROS, AT Innsbruck MitoCom


Labels: MiParea: Respiration, Instruments;methods, Comparative MiP;environmental MiP 


Tissue;cell: Heart, Liver  Preparation: Homogenate 


Coupling state: LEAK, OXPHOS, ETS"ETS" is not in the list (LEAK, ROUTINE, OXPHOS, ET) of allowed values for the "Coupling states" property. 

HRR: Oxygraph-2k, Protocol"Protocol" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property. 

O2k-Demo, Mt-Preparation, Auxiliary, PBI-Shredder, O2k-Core 

Further information

>> PBI-Shredder HRR-Set
>> PermeabilizedFibrePreparation