Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "MiPNet17.03 Shredder vs Fibers"

From Bioblast
Line 1: Line 1:
{{Publication
{{Publication
|title=Doerrier C, Draxl A, Wiethuechter A, Eigentler A, Gnaiger E. PBI-Shredder_Fish-heart-liver: Mitochondrial Respiration in Permeabilized Fibres versus Homogenate from Trout Heart and Liver. Mitochondr Physiol Network 17.03.
|title=Doerrier C, Draxl A, Wiethuechter A, Eigentler A, Gnaiger E. Mitochondrial respiration in permeabilized fibres versus homogenate from fish liver and heart. An application study with the PBI-Shredder. Mitochondr Physiol Network 17.03.
|info=[http://oroboros.at/?Shredder_vs_Fibres MiPNet17.03 Open Access]
|info=[http://oroboros.at/?Shredder_vs_Fibres MiPNet17.03 Open Access]
|authors=Doerrier C, Draxl A, Wiethuechter A, Eigentler A, Gnaiger E
|authors=Doerrier C, Draxl A, Wiethuechter A, Eigentler A, Gnaiger E

Revision as of 15:20, 21 June 2013

Publications in the MiPMap
Doerrier C, Draxl A, Wiethuechter A, Eigentler A, Gnaiger E. Mitochondrial respiration in permeabilized fibres versus homogenate from fish liver and heart. An application study with the PBI-Shredder. Mitochondr Physiol Network 17.03.

Β» MiPNet17.03 Open Access

Doerrier C, Draxl A, Wiethuechter A, Eigentler A, Gnaiger E (

) Mitochondr Physiol Network

Abstract: In the present study we compared mitochondrial function of permeabilized fibres and homogenate of heart muscle of mice. In addition, respiration of trout heart homogenate preparations were compared with permeabilized fibres, and the PBI-Shredder was successfully tested with preparation of trout liver. β€’ Keywords: Tissue homogenate, shredder

β€’ O2k-Network Lab: AT_Innsbruck_OROBOROS, AT_Innsbruck_Gnaiger E, AT Innsbruck MitoCom


Labels:


Tissue;cell: Heart, Liver  Preparation: Homogenate 


Coupling state: LEAK, OXPHOS, ETS"ETS" is not in the list (LEAK, ROUTINE, OXPHOS, ET) of allowed values for the "Coupling states" property. 

HRR: Oxygraph-2k, Protocol"Protocol" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property., MiPNet-Publication"MiPNet-Publication" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property. 

mt-Preparation 

  • First on-line version: 2012-05-14.