Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "FCCP"

From Bioblast
Line 3: Line 3:
|description=Carbonyl cyanide p-(trifluoro-methoxy) phenyl-hydrazone (C<sub>10</sub>H<sub>5</sub>F<sub>3</sub>N<sub>4</sub>O); [[uncoupler]], F(x): '''FCCP''' added at concentration x.
|description=Carbonyl cyanide p-(trifluoro-methoxy) phenyl-hydrazone (C<sub>10</sub>H<sub>5</sub>F<sub>3</sub>N<sub>4</sub>O); [[uncoupler]], F(x): '''FCCP''' added at concentration x.
|info=[[MiPNet10.04]]; [[SteinlechnerMaran_1996_AJP]]
|info=[[MiPNet10.04]]; [[SteinlechnerMaran_1996_AJP]]
|type=Uncoupler
}}
{{MitoPedia topics
|mitopedia topic=Uncoupler
|type=Uncoupler
|type=Uncoupler
}}
}}

Revision as of 14:37, 9 March 2011


high-resolution terminology - matching measurements at high-resolution


FCCP

Description

Carbonyl cyanide p-(trifluoro-methoxy) phenyl-hydrazone (C10H5F3N4O); uncoupler, F(x): FCCP added at concentration x.

Abbreviation: Fx

Reference: MiPNet10.04; SteinlechnerMaran_1996_AJP


MitoPedia topics: Uncoupler 


Labels:




Regulation: Respiration; OXPHOS; ETS Capacity"Respiration; OXPHOS; ETS Capacity" is not in the list (Aerobic glycolysis, ADP, ATP, ATP production, AMP, Calcium, Coupling efficiency;uncoupling, Cyt c, Flux control, Inhibitor, ...) of allowed values for the "Respiration and regulation" property. 


HRR: Chemicals; Media"Chemicals; Media" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property. 


Application in HRR

F: FCCP (Carbonyl cyanide 4-(trifluoromethoxy)phenylhydrazone, C10H5F3N4O); Sigma C 2920, 10 mg, store at 4 °C: FW = 254.17)

Caution: Chemicals stored in the fridge or freezer should be allowed to reach room temperature before opening.


Preparation of 1 mM stock solution (dissolved in 99.9% Ethanol):

1) weigh 1.27 mg of FCCP into a glass vial and dissolve in 5 ml Ethanol
2) divide into 0.2 ml portions OR store in 5 ml glass vial and use subsamples during experiments to avoid contamination of the stock solution
3) store in glass vials (recommendation) at -20 °C

Oxygraph-2k Manual Titrations: MiPNet09.12

  • Titration volume: 1 µl steps using a 10 µl syringe
  • Final conc. in 2 ml O2k-chamber: 0.5 µM steps

Frequently, more diluted FCCP for getting several titration steps is necessary. In this case prepare more diluted solution (ditution 2-10x) from your stock solution.