Difference between revisions of "E-R control efficiency"
Line 1: | Line 1: | ||
{{MitoPedia | {{MitoPedia | ||
|abbr='' | |abbr=''j<sub>ExR</sub>'' | ||
|description=The apparent '''ETS excess factor over ''R''''' (''E-R'' coupling control factor), '' | |description=The apparent '''ETS excess factor over ''R''''' (''E-R'' coupling control factor), ''j<sub>ExR</sub>'' = (''E-R'')/''E'' = 1-''R/E'', is an expression of the relative scope of increasing [[ROUTINE respiration]] in intact cells by uncoupling. ''j<sub>ExR</sub>'' = 0.0 for zero excess capacity when ''R''=''E''; ''j<sub>ExR</sub>'' = 1.0 for the maximum limit when ''R''=0. The [[ROUTINE]] state of intact cells is stimulated to [[ETS]] by [[uncoupler]] titration. Since ETS capacity is significantly higher than OXPHOS capacity in various cell types (as shown by '''''[[cell ergometry]]'''''), ''E-R'' or ''j<sub>ExR</sub>'' is not a reseve capacity available for the cell to increase oxidative phosphorylation, but strictly a scope (reserve?) for uncoupling respiration. | ||
|info=[[Flux control factor]] | |info=[[Flux control factor]] | ||
}} | }} | ||
Line 12: | Line 12: | ||
== Compare == | == Compare == | ||
* [[ETS excess factor over P |ETS excess factor over ''P'']] | * [[ETS excess factor over P |ETS excess factor over ''P'']] | ||
* ''More details:'' [[ | * ''More details:'' [[ETS coupling efficiency]] |
Revision as of 22:12, 25 August 2014
Description
The apparent ETS excess factor over R (E-R coupling control factor), jExR = (E-R)/E = 1-R/E, is an expression of the relative scope of increasing ROUTINE respiration in intact cells by uncoupling. jExR = 0.0 for zero excess capacity when R=E; jExR = 1.0 for the maximum limit when R=0. The ROUTINE state of intact cells is stimulated to ETS by uncoupler titration. Since ETS capacity is significantly higher than OXPHOS capacity in various cell types (as shown by cell ergometry), E-R or jExR is not a reseve capacity available for the cell to increase oxidative phosphorylation, but strictly a scope (reserve?) for uncoupling respiration.
Abbreviation: jExR
Reference: Flux control factor
MitoPedia methods:
Respirometry
MitoPedia topics: "Respiratory control ratio" is not in the list (Enzyme, Medium, Inhibitor, Substrate and metabolite, Uncoupler, Sample preparation, Permeabilization agent, EAGLE, MitoGlobal Organizations, MitoGlobal Centres, ...) of allowed values for the "MitoPedia topic" property.
Respiratory control ratio"Respiratory control ratio" is not in the list (Enzyme, Medium, Inhibitor, Substrate and metabolite, Uncoupler, Sample preparation, Permeabilization agent, EAGLE, MitoGlobal Organizations, MitoGlobal Centres, ...) of allowed values for the "MitoPedia topic" property.
Compare
- ETS excess factor over P
- More details: ETS coupling efficiency