Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "E-R control efficiency"

From Bioblast
Line 1: Line 1:
{{MitoPedia
{{MitoPedia
|abbr=''j<sub>E-R</sub>'', ''CCF<sub>E-R</sub>''
|abbr=''Ex<sub>R</sub>/E''
|description=The '''''E-R'' coupling control factor''', ''j<sub>E-R</sub>'' = (''E-R'')/''E'', is the '''apparent ETS excess capacity over ''R'''''; 0.0 for zero excess capacity when ''R''=''E''; 1.0 for the maximum limit when ''R''=0. The [[ROUTINE]] state of intact cells is stimulated to [[ETS]] by [[uncoupler]] titration.
|description=The apparent '''ETS excess factor over ''R''''' (''E-R'' coupling control factor), ''Ex<sub>R</sub>/E'' = (''E-R'')/''E'', is an expression of the relative scope of increasing [[ROUTINE respiration]] by uncoupling. ''Ex<sub>R</sub>/E'' = 0.0 for zero excess capacity when ''R''=''E''; ''Ex<sub>R</sub>/E'' = 1.0 for the maximum limit when ''R''=0. The [[ROUTINE]] state of intact cells is stimulated to [[ETS]] by [[uncoupler]] titration.
|info=[[Flux control factor]]
|info=[[Flux control factor]]
}}
}}
Line 10: Line 10:
|mitopedia topic=Respiratory control ratio
|mitopedia topic=Respiratory control ratio
}}
}}
== Biochemical coupling efficiency: from 0 to <1 ==
== Compare ==
* [[ETS excess factor over P |ETS excess factor over ''P'']]
* ''More details:'' [[Biochemical coupling efficiency]]
* ''More details:'' [[Biochemical coupling efficiency]]
* Compare [[ROUTINE control ratio]] per ETS (phosphorylation system control ratio)

Revision as of 13:14, 9 August 2014


high-resolution terminology - matching measurements at high-resolution


E-R control efficiency

Description

The apparent ETS excess factor over R (E-R coupling control factor), ExR/E = (E-R)/E, is an expression of the relative scope of increasing ROUTINE respiration by uncoupling. ExR/E = 0.0 for zero excess capacity when R=E; ExR/E = 1.0 for the maximum limit when R=0. The ROUTINE state of intact cells is stimulated to ETS by uncoupler titration.

Abbreviation: ExR/E

Reference: Flux control factor


MitoPedia methods: Respirometry 


MitoPedia topics: "Respiratory control ratio" is not in the list (Enzyme, Medium, Inhibitor, Substrate and metabolite, Uncoupler, Sample preparation, Permeabilization agent, EAGLE, MitoGlobal Organizations, MitoGlobal Centres, ...) of allowed values for the "MitoPedia topic" property. Respiratory control ratio"Respiratory control ratio" is not in the list (Enzyme, Medium, Inhibitor, Substrate and metabolite, Uncoupler, Sample preparation, Permeabilization agent, EAGLE, MitoGlobal Organizations, MitoGlobal Centres, ...) of allowed values for the "MitoPedia topic" property. 

Compare