|description=The '''''E-R'' coupling control factor''',Β  ''j<sub>E-R</sub>'', is the '''apparent ETS excess capacity over ''R'''''; 0.0 for zero excess capacity when ''R''=''E''. The [[ROUTINE]] state of intact cells is stimulated to [[ETS]] by [[uncoupler]] titration.
|description=The '''''E-R'' coupling control factor''',Β  ''j<sub>E-R</sub>'' = (''E-R'')/''E'', is the '''apparent ETS excess capacity over ''R'''''; 0.0 for zero excess capacity when ''R''=''E''; 1.0 for the maximum limit when ''R''=0. The [[ROUTINE]] state of intact cells is stimulated to [[ETS]] by [[uncoupler]] titration.
|info=[[Flux control factor]]
|info=[[Flux control factor]]
}}
}}

Revision as of 08:18, 9 August 2014


high-resolution terminology - matching measurements at high-resolution


E-R control efficiency

Description

The E-R coupling control factor, jE-R = (E-R)/E, is the apparent ETS excess capacity over R; 0.0 for zero excess capacity when R=E; 1.0 for the maximum limit when R=0. The ROUTINE state of intact cells is stimulated to ETS by uncoupler titration.

Abbreviation: jE-R, CCFE-R

Reference: Flux control factor


MitoPedia methods: Respirometry 


MitoPedia topics: "Respiratory control ratio" is not in the list (Enzyme, Medium, Inhibitor, Substrate and metabolite, Uncoupler, Sample preparation, Permeabilization agent, EAGLE, MitoGlobal Organizations, MitoGlobal Centres, ...) of allowed values for the "MitoPedia topic" property. Respiratory control ratio"Respiratory control ratio" is not in the list (Enzyme, Medium, Inhibitor, Substrate and metabolite, Uncoupler, Sample preparation, Permeabilization agent, EAGLE, MitoGlobal Organizations, MitoGlobal Centres, ...) of allowed values for the "MitoPedia topic" property. 

Biochemical coupling efficiency: from 0 to <1