== Application in [[HRR]] ==
== Application in [[HRR]] ==


:::: '''Closed chamber''' means that the experimental chamber and the capillary of the stopper are filled with liquid and no air space or bubble is present in the chamber with the stopper fully inserted into the volume-calibrated position. Any titrations are performed between closed states, but not during a closed state. For closing the chamber without a gas bubble, an excessive volume of liquid has to be present in the chamber (minimum 2.1 mL for the 2-mL chamber; 0.55 mL for the 0.5-mL chamber). The stirrer can be switched on. Any foam should be avoided. Before inserting the stopper, the capillary of the stopper must be free of aqueous medium. The conical shape of the standard stopper facilitates bubble-free closing of the chamber with stirrers switched on - the bubbles escape through the central capillary. After closing the chamber the excessive liquid must be aspirated from the receptacle of the stopper.  
:::: '''Closed chamber''' means that the experimental chamber and the capillary of the stopper are filled with liquid and no air space or bubble is present in the chamber with the stopper fully inserted into the volume-calibrated position. Any titrations are performed between closed states, but not during a closed state. For closing the chamber without a gas bubble, an excessive volume of liquid has to be present in the chamber (minimum 2.1 mL for the 2-mL chamber; 0.54 mL for the 0.5-mL chamber). The stirrer can be switched on. Any foam should be avoided. Before inserting the stopper, the capillary of the stopper must be free of aqueous medium. The conical shape of the standard stopper facilitates bubble-free closing of the chamber with stirrers switched on - the bubbles escape through the central capillary. After closing the chamber the excessive liquid must be aspirated from the receptacle of the stopper.  
:::: The procedure of bubble-free closing a chamber with a multisensor stopper is described in the manual for ion selective electrodes [[MiPNet15.03]].
:::: The procedure of bubble-free closing a chamber with a multisensor stopper is described in the manual for ion selective electrodes [[MiPNet15.03]].



Revision as of 10:14, 7 September 2020


                  


O2k-Open Support

Closed chamber



Template NextGen-O2k.jpg


MitoPedia O2k and high-resolution respirometry: O2k-Open Support 



Description

The O2k chamber can be used as a closed system or open system. Gas bubbles must be avoided.

Abbreviation: C

Reference: System

Application in HRR

Closed chamber means that the experimental chamber and the capillary of the stopper are filled with liquid and no air space or bubble is present in the chamber with the stopper fully inserted into the volume-calibrated position. Any titrations are performed between closed states, but not during a closed state. For closing the chamber without a gas bubble, an excessive volume of liquid has to be present in the chamber (minimum 2.1 mL for the 2-mL chamber; 0.54 mL for the 0.5-mL chamber). The stirrer can be switched on. Any foam should be avoided. Before inserting the stopper, the capillary of the stopper must be free of aqueous medium. The conical shape of the standard stopper facilitates bubble-free closing of the chamber with stirrers switched on - the bubbles escape through the central capillary. After closing the chamber the excessive liquid must be aspirated from the receptacle of the stopper.
The procedure of bubble-free closing a chamber with a multisensor stopper is described in the manual for ion selective electrodes MiPNet15.03.
» Compare: Open chamber