|description=The [[Oxygraph-2k]] is a MultiChannel instrument. A '''channel''' is defined in [[DatLab]] in terms of the recorded signal type, which is the Oxygen channel (O2, amperometric), the additional amperometric channel (Amp), and the potentiometric channel (px). Each of the two chambers of the O2k supports these three channels. In addition, O2k system channels are recorded, which are the [[barometric pressure]], [[block temperature]], environmental temperature, and additional external temperature, and the [[Peltier power]].
|description=The [[Oxygraph-2k]] is a MultiChannel instrument. A '''channel''' is defined in [[DatLab]] in terms of the recorded signal type, which is the Oxygen channel (O2, amperometric), the additional amperometric channel (Amp), and the potentiometric channel (px). Each of the two chambers of the O2k supports these three channels. In addition, O2k system channels are recorded, which are the [[barometric pressure]], [[block temperature]], environmental temperature, and additional external temperature, and the [[Peltier power]].
|info=[[MiPNet19.18A O2k-Start]], [[MiPNet17.05 O2k-Fluo LED2-Module]], [[MiPNet15.03 O2k-MultiSensor-ISE]], [[MiPNet15.05 NO-Manual]]
|info=[[MiPNet19.18A O2k-Start]], [[MiPNet17.05 O2k-Fluo LED2-Module]], [[MiPNet15.03 O2k-MultiSensor-ISE]], [[MiPNet15.05 NO-Manual]]

Revision as of 07:37, 2 February 2016


high-resolution terminology - matching measurements at high-resolution


Channel

Description

The Oxygraph-2k is a MultiChannel instrument. A channel is defined in DatLab in terms of the recorded signal type, which is the Oxygen channel (O2, amperometric), the additional amperometric channel (Amp), and the potentiometric channel (px). Each of the two chambers of the O2k supports these three channels. In addition, O2k system channels are recorded, which are the barometric pressure, block temperature, environmental temperature, and additional external temperature, and the Peltier power.

Abbreviation: F7

Reference: MiPNet19.18A O2k-Start, MiPNet17.05 O2k-Fluo LED2-Module, MiPNet15.03 O2k-MultiSensor-ISE, MiPNet15.05 NO-Manual



MitoPedia methods: Respirometry, Fluorometry, Spectrophotometry, "DatLab" is not in the list (Respirometry, Fluorometry, Spectrophotometry) of allowed values for the "MitoPedia method" property. DatLab 