Scherz 2017 PLOS One

From Bioblast
Publications in the MiPMap
Scherz V, Durussel C & Greub G (2017) Internal quality assurance in diagnostic microbiology: A simple approach for insightful data. PLOS One 12(11):e0187263.

Β» PMID:29135992 Open Access

Scherz V, Durussel C & Greub G (2017) PLOS One

Abstract: Given the importance of microbiology results on patient care, high quality standards are expected. Internal quality assurance (IQA) could mitigate the limitations of internal quality control, competency assessment and external quality assurance, adding a longitudinal insight, including pre- and post-analytical steps. Here, we implemented an IQA program in our clinical microbiology facilities with blind resubmission of routine samples during 22 months. One-hundred-and-twenty-one out of 123 (98.4%) serological analyses and 112 out of 122 (91.8%) molecular analyses were concordant. Among the discordances in molecular biology analyses, 6 results were low positive samples that turned out negative, likely due to stochastic repartition of nucleic acids. Moreover, one identified retranscription error led us to implement automated results transmission from the Applied Biosystems instruments to the laboratory information system (LIS). Regarding Gram stain microscopy, 560 out of 745 (75.2%) of compared parameters were concordant. As many as 67 out of 84 (79.8%) pairs of culture results were similar, including 16 sterile pairs, 27 having identical identification or description and semi-quantification and 24 only showing variations in semi-quantification with identical description or identification of colonies. Seventeen pairs had diverging identification or description of colonies. Culture was twice only done for one member of the pairs. Regarding antibiotic susceptibility testing, a major discrepancy was observed in 5 out of 48 results (10.4%). In conclusion, serological tests were highly reproducible. Molecular diagnosis also revealed to be robust except when the amounts of nucleic acids present in the sample were close to the limits of detection. Conventional microbiology was less robust with major discrepancies reaching 39.5% of the samples for microscopy. Similarly, culture and antibiotic susceptibility testing were prone to discrepancies. This work was ground for reconsidering multiples aspects of our practices and demonstrates the importance of IQA to complete the other quality management procedures.

β€’ Bioblast editor: Iglesias-Gonzalez J

Cited by

  • Iglesias-Gonzalez et al (2021) Proficiency test in mt-respiration: A necessary tool for reliable and reproducible results. MitoFit Preprints 2021 (in prep).

Labels:






MitoFit 2021 PT 

Cookies help us deliver our services. By using our services, you agree to our use of cookies.