Lanza 2011 J Magnetic Resonance Imaging

From Bioblast
Jump to navigation Jump to search
Publications in the MiPMap
Lanza IR, Bhagra S, Nair KS, Port JD (2011) Measurement of human skeletal muscle oxidative capacity by 31P-MR spectroscopy: A cross-validation with in vitro measurements. J Magnetic Resonance Imaging DOI: 10.1002/jmri.22733.

» PMID:22006551

Lanza IR, Bhagra S, Nair KS, Port JD (2011) J Magnetic Resonance Imaging

Abstract: Purpose: To cross-validate skeletal muscle oxidative capacity measured by 31P-MR spectroscopy with in vitro measurements of oxidative capacity in mitochondria isolated from muscle biopsies of the same muscle group in 18 healthy adults.

Materials and Methods: Oxidative capacity in vivo was determined from PCr recovery kinetics following a 30-s maximal isometric knee extension. State 3 respiration was measured in isolated mitochondria using high-resolution respirometry. A second cohort of 10 individuals underwent two 31P-MRS testing sessions to assess the test–retest reproducibility of the method.

Results: Overall, the in vivo and in vitro methods were well-correlated (r = 0.66–0.72) and showed good agreement by Bland Altman plots. Excellent reproducibility was observed for the PCr recovery rate constant (CV = 4.6%; ICC = 0.85) and calculated oxidative capacity (CV = 3.4%; ICC = 0.83).

Conclusion: These results indicate that 31P-MRS corresponds well with gold-standard in vitro measurements and is highly reproducible. Keywords: phosphocreatine recovery;skeletal muscle;high-resolution respirometry;mitochondria;oxidative capacity

O2k-Network Lab: US MN Rochester Nair KS


Labels:


Organism: Human  Tissue;cell: Skeletal muscle  Preparation: Isolated mitochondria 


Coupling state: OXPHOS 

HRR: Oxygraph-2k