Abstract: Current assessment of pre-operative liver function relies upon biochemical blood tests and histology but these only indirectly measure liver function. Mitochondrial function (MF) analysis allows direct measurement of cellular metabolic function and may provide an additional index of hepatic health. Conventional MF analysis requires substantial tissue samples (>100 mg) obtained at open surgery. Here we report a method to assess MF using <3 mg of tissue obtained by a Tru-cutยฎ biopsy needle making it suitable for percutaneous application.
An 18G Bardยฎ Max-coreยฎ biopsy instrument was used to collect samples. The optimal Tru-cutยฎ sample weight, stability in ice-cold University of Wisconsin solution, reproducibility and protocol utility was initially evaluated in Wistar rat livers then confirmed in human samples. MF was measured in saponin-permeabilized samples using high-resolution respirometry.
The average mass of a single rat and human liver Tru-cutยฎ biopsy was 5.60ยฑ0.30 and 5.16ยฑ0.15 mg, respectively (mean; standard error of mean). Two milligram of sample was found the lowest feasible mass for the MF assay. Tissue MF declined after 1 hour of cold storage. Six replicate measurements within rats and humans (n = 6 each) showed low coefficient of variation (<10%) in measurements of State-III respiration, electron transport chain (ETC) capacity and respiratory control ratio (RCR). Ischemic rat and human liver samples consistently showed lower State-III respiration, ETC capacity and RCR, compared to normal perfused liver samples.
Consistent measurement of liver MF and detection of derangement in a disease state was successfully demonstrated using less than half the tissue from a single Tru-cutยฎ biopsy. Using this technique outpatient assessment of liver MF is now feasible, providing a new assay for the evaluation of hepatic function. โข Keywords: Tru-cutยฎ
โข O2k-Network Lab: NZ Auckland Hickey AJ
Labels: MiParea: Respiration, Instruments;methods
Organism: Human, Rat
Tissue;cell: Liver
Preparation: Permeabilized tissue
Coupling state: LEAK, OXPHOS, ET
Pathway: N, ROX
HRR: Oxygraph-2k