Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "Stirrer-Bar\white PVDF\15x6 mm"

From Bioblast
(Created page with "{{Product |description='''Stirrer bar PVDF''', 15x6 mm, operated in the O2k chamber at constant stirring speed (standard is 750 rpm, or 12.5 Hz), to provide optimum m...")
 
 
(45 intermediate revisions by 13 users not shown)
Line 1: Line 1:
{{Product
{{Technical support}}
|description='''[[Stirrer bar PVDF]]''', 15x6 mm, operated in the [[O2k]] [[chamber]] at constant stirring speed (standard is 750 rpm, or 12.5 Hz), to provide optimum mixing of the sample in the aqueous medium and ensure a stable signal of the polarographic oxygen sensor ([[POS]]) placed in a position of maximum current of the medium.
__TOC__
|product id=23210-24
{{MitoPedia without banner
|product type=O2k
|abbr=
|info=MiPNet06.01
|description=[[Image:Stirrer bar PVDF.jpg|right|180px]]'''Stirrer-Bar\white [[PVDF]]\15x6 mm''', operated in the 2-mL [[O2k-chamber]] at constant stirring speed (standard is 750 rpm, or 12.5 Hz), to provide optimum mixing of the sample in the aqueous medium and ensure a stable signal of the polarographic oxygen sensor ([[OroboPOS]]) placed in a position of maximum current of the medium.
 
|info=[https://www.oroboros.at/index.php/product/stirrer-barwhite-pvdf15x6-mm/ '''Product details and purchase information''']
}}
 
 
== Technical support ==
:::* A "jumping" stirring bar problem is frequently caused by small particles sticking to the glass chamber, not the stirring bar itself.
:::* A stirring bar rotating slowly or not smoothly, may indicate a “demagnetization” of the stirrer itself, caused by the contact with a strong magnet. Please keep the stirrer away from magnetic fields.
::::» [[MiPNet19.03 O2k-cleaning and ISS]].
 
 
== Keywords ==
{{Template:Keywords: Chamber volume}}
 
 
{{MitoPedia O2k and high-resolution respirometry
|mitopedia O2k and high-resolution respirometry=O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry
}}
}}

Latest revision as of 17:59, 15 March 2023


                  


O2k-Open Support

Stirrer-Bar\white PVDF\15x6 mm



Template NextGen-O2k.jpg


MitoPedia O2k and high-resolution respirometry: O2k-Open Support 



Description

Stirrer bar PVDF.jpg

Stirrer-Bar\white PVDF\15x6 mm, operated in the 2-mL O2k-chamber at constant stirring speed (standard is 750 rpm, or 12.5 Hz), to provide optimum mixing of the sample in the aqueous medium and ensure a stable signal of the polarographic oxygen sensor (OroboPOS) placed in a position of maximum current of the medium.


Reference: Product details and purchase information


Technical support

  • A "jumping" stirring bar problem is frequently caused by small particles sticking to the glass chamber, not the stirring bar itself.
  • A stirring bar rotating slowly or not smoothly, may indicate a “demagnetization” of the stirrer itself, caused by the contact with a strong magnet. Please keep the stirrer away from magnetic fields.
» MiPNet19.03 O2k-cleaning and ISS.


Keywords


Questions.jpg


Click to expand or collaps



MitoPedia O2k and high-resolution respirometry: O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry