OROBOROS O2k-Catalogue

From Bioblast
Jump to: navigation, search

OROBOROS INSTRUMENTS

OROBOROS         Products         Purchase         Support         O2k-Publications         Workshops & Events         O2k-Network         Feedback         Contact



OROBOROS O2k-Catalogue

- a guided tour to the O2k technology
O2k-Catalogue
O2k-Concept.jpg


» O2k-Catalogue: Contents and concept
» Order information: Purchase




ID group Product Including
1#### O2k,

O2k-Fluorometer

the modular system for high-resolution respirometry
2#### O2k-Core OroboPOS, ISS, DatLab
3#### TIP2k
4#### O2k-MultiSensor O2k-Fluo, O2k-TPP+, O2k-pH, O2k-NO
5#### Core-Accessories and Auxiliary HRR-Tools Titration-Tools / PBI-Shredder HRR-Set / Microbalance / HRR-Dissection Tools /

Motic Microscope

» Complete OROBOROS Product List: including former series, all spares.

O2k-Catalogue OROBOROS - all products in current series

TitleProduct descriptionProduct IDImage
O2k-Catalogue: Contents and conceptO2k-Catalogue: Contents and concept
OROBOROS Oxygraph-2k Logo.jpg
O2k versus multiwell respirometerO2k versus multiwell respirometer: O2k stands for Oxygraph-2k and high-resolution respirometry, meeting powerful quality criteria securing high output and pioneering state-of-the-art comprehensive OXPHOS analysis of substrate control and coupling control of mitochondrial function. 'High throughput' stands for disposable multiwell systems - expensive, with limited scope and extremely high running costs. In respirometry, high throughput is not equivalent to high output. If you’re using a biased instrument, it doesn’t matter how many measurements you take – you’re aiming at the wrong target (Silver 2012 Penguin Press).
O2k-Info.png
Oxygraph-2kOROBOROS Oxygraph-2k (O2k) - the modular system for high-resolution respirometry (HRR). The O2k is the 2-chamber high-resolution respirometer for monitoring oxygen consumption with small amounts of biological samples. The modular O2k-concept yields a high flexibility for HRR, with the O2k-Core as the basis, and O2k-Modules supported by the O2k-Core. O2k-Modules are the Titration-Injection microPump (TIP2k-Module) and O2k-MultiSensor Modules (O2k-Fluorometer; Ion Selective Electrodes, ISE)1####
O2k.jpg
O2k-CoreOROBOROS O2k-Core - the experimental system complete for basic high-resolution respirometry (HRR). The O2k-Core includes the O2k-Main Unit with stainless steel housing, O2k-Assembly Kit, two OroboPOS (polarographic oxygen sensors) and OroboPOS-Service Kit, DatLab software, the ISS-Integrated Suction System and the O2k-Titration Set. The O2k-Core supports all add-on O2k-Modules of the O2k, and is a component of the O2k-Fluorometer.

On-line display of oxygen flux (rate of respiration) is provided in addition to the conventional 'oxygraphic' plot of oxygen concentration over time. Highest signal stability minimizes the required amounts of biological sample, and provides the basis for resolution in the extreme low-oxygen range. Peltier temperature control provides a thermal stability at ±0.002 °C in the range of 4 °C to 47 °C at typical constant room temperature. Electronically controlled PVDF or PEEK stirrers are integrated in the two-chamber design of the O2k, and a barometric pressure transducer enables automatic oxygen calibrations implemented in the DatLab software.

The O2k is a sole source apparatus with no other instruments meeting its specifications.
10000-02
O2k-Core-Concept.jpg
Power-O2k
Power-O2k

Power-O2k Core-Unit: The Power-O2k Core Unit is an economical option for using additional O2k-Units to increase output in high-resolution respirometry. This application does not require an additional ISS-Integrated Suction System, an O2k-Titration Set and the O2k-Manual. Furthermore, the following OroboPOS Service Tools can be used from the available O2k-Core and are not included: OroboPOS-Mounting Tool, OroboPOS-Polishing Cloth, OroboPOS-Polishing Powder and Pen-Contact Oil.

The Power-O2k Core-Unit supports all add-on O2k-Modules of the Oxygraph-2k.
10001-01
O2k-FluorometerO2k-Fluorometer (OROBOROS O2k-Fluorometer, OROBOROS Oxygraph-2k Fluorometer) - the experimental system complete for high-resolution respirometry (HRR) combined with fluorometry. The O2k-Fluorometer includes the O2k-Core, O2k-Fluo LED2-Module and TIP2k, and supports all other add-on O2k-Modules of the Oxygraph-2k. The O2k is a sole source apparatus with no other instruments meeting its specifications.10010-01
O2k-Fluorometer
Power O2k-FluorometerPower O2k-Fluorometer (OROBOROS Power O2k-Fluorometer) - Optional configuration as additional system for increasing output in high-resolution respirometry (HRR) combined with fluorometry. The Power O2k-Fluorometer includes the Power-O2k Core-Unit, O2k-Fluo LED2-Module and TIP2k, and supports all other add-on O2k-Modules of the Oxygraph-2k. It can be added to an existing O2k-Core or O2k-Fluorometer. This application does not require an additional ISS-Integrated Suction System, an O2k-Titration Set and the O2k-Manual. Furthermore, the following OroboPOS Service Tools can be used from the available O2k-Core and are not included: OroboPOS-Mounting Tool, OroboPOS-Polishing Cloth, OroboPOS-Polishing Powder and Pen-Contact Oil. The O2k is a sole source apparatus with no other instruments meeting its specifications.10011-01
O2k-Fluorometer
TIP2k-ModuleTIP2k-Module - Titration-Injection microPump (TIP2k) for two-channel operation with the O2k-Core with automatic control by DatLab of programmable titration regimes and feedback control (oxystat, pH-stat). The TIP2k-Module includes TIP2k-Accessories: 4 Microinjection syringes, 1 Pkg. TIP2k-Needle Spacers with mounting tool, 1 TIP2k-Needle Safety Support and 1 Pkg. TIP2k Filter Papers.11100-02
TIP2k with 200 mm3 microsyringe.JPG
O2k-Fluo LED2-ModuleThe O2k-Fluo LED2-Module is a component of the O2k-Fluorometer. It is an amperometric add-on module to the O2k-Core (Series D upwards), adding a new dimension to HRR. Optical sensors are inserted through the front window of the O2k-glass chambers, for measurement of hydrogen peroxide production (Amplex red), ATP production (Magnesium green), mt-membrane potential (Safranin, TMRM), Ca2+ (Calcium green), and numerous other applications open for O2k-user innovation. The O2k-Fluo LED2-Module consists of optical sensors for both O2k-Chambers (LEDs for green and blue excitation), optical filters, Fluorescence-Control Unit for regulation of light intensity, data input into the O2k-Main Unit, and the updated DatLab software.12100-01
Fluorescence-Control Unit lettered.jpg
O2k-TPP+ ISE-ModuleO2k-TPP+ ISE-Module: 2 potentiometric ion-selective electrodes (ISE), ISE-Service Kit and 2 PEEK-Stoppers, supported by the O2k-Core. The ISE module is designed with replaceable membranes making it possible to measure different ions such as TPP+ or Ca2+ with the same electrode housing. The main application of the O2k-TPP+ ISE-Module is measurement of mitochondrial membrane potential with tetraphenylphosphonium (TPP+) or TPMP+.12300-02
O2k-TPP-ISE.jpg
O2k-pH ISE-ModuleO2k-pH ISE-Module: two pH electrodes and reference electrodes and accessories, two black PEEK stoppers, supported by the O2k-Core.12400-01
O2k-NO Amp-ModuleO2k-NO Amp-Module: 2 black PEEK stoppers for amperometric O2k-MultiSensor application (NO, H2S, H2O2); 1 additional hole (2.3 mm); central titration port; conical bottom; with Volume-Calibration Rings (A and B); with 8 spare O-rings (O-ring\Viton\12x1 mm; two boxes). The NO sensor is not included.12500-02
O2k-NO Amp-Module.jpg
PBI-Shredder HRR-SetPBI-Shredder HRR-Set: Auxiliary HRR-Tool for tissue homogenate preparation; the Shredder-Kit Box contains the heavy duty high torque SG3 driver with convertible handle, SG3 base with 3 position force setting lever (FSL), battery charger, two lithium ion batteries, Shredder-Tube Cap Tool and Shredder-Tube Ram Tool. The PBI-Shredder HRR-Set includes the Shredder-Kit Box with 100 Shredder-Tubes FT500-PS, 100 Shredder-Tubes FT500-PMS, a pair of sharp forceps for tissue dissection, a pair of scissors and a manual. OROBOROS INSTRUMENTS: world-wide distributor.13200-04
PBI-Shredder HRR-Set.JPG
Microbalance-SetMicrobalance-Set: Microbalance 120 g (41 g to 120 g; 0.01 mg / 0.1 mg display) with Microbalance-Transport Case; particularly for wet weight determination of permeabilized fibres. Input 100 to 240 V.13300-01
Microbalance Set.jpg
HRR-Dissection SetHRR-Dissection Set: for tissue preparation, set of 4 pairs of stainless steel, antimagnetic forceps and a pair of scissors.13400-01
Forcep for tissue preparation angular tip.jpg
O2k-Main UnitThe O2k-Main Unit is a component of the O2k-Core. The O2k-Main Unit consists of functionally defined, integral elements, the (O2k-Main Basic, O2k-Peltier Temperature Control, two O2k-Electromagnetic Stirrer Twin-Control units, two O2k-Amperometric OroboPOS Twin-Channels, O2k-Barometric Pressure Transducer), which cannot be obtained separately.20000
O2k-Main BasicThe O2k-Main Basic is an integral element of the O2k-Main Unit. The Oxygraph-2k Main Basic has the following components:
  • Stainless-Steel Housing
  • Switching power supply
  • Microprocessor for integrated control, A/D converters and data handling
  • Copper-Block with windows to 2 O2k-Chambers
  • 2 Amperometric OroboPOS Plugs
  • TIP2k socket, providing the basis for add-on of the TIP2k
  • 2 Potentiometric Plugs for ion sensitive electrodes (ISE: TPP+, Ca2+; pH), providing the basis for add-on of the O2k-MultiSensor Modules
  • 2 Amperometric Plugs, providing the basis for add-on of the O2k-Fluo LED2-Module or NO (H2S) sensors.
  • USB-Port for connection with DatLab (PC or laptop not included)
20010
O2k-Peltier Temperature ControlO2k-Peltier Temperature Control: electronic thermostat controlling temperature for 2 O2k-Chambers in the range of 4 to 47 °C; ±0.002 °C. Continuous recording of the O2k-Copper Block temperature. Integral component of the O2k-Main Unit.20020
O2k-Electromagnetic Stirrer Twin-ControlO2k-Electromagnetic Stirrer Twin-Control for smooth rotation of the stirrer bars in the two O2k-Chambers; with slow-start function to prevent decoupling of the stirrer bar; regulated stirrer speed in the range of 100 to 800 rpm (decoupling may occur at higher stirrer speeds), independent for the two O2k-Chambers; automatic events sent to DatLab when the stirrer is switched on/off or when the rotation seed is changed by the experimenter. Integral component of the O2k-Main Unit.20030
O2k-Amperometric OroboPOS Twin-ChannelO2k-Amperometric OroboPOS Twin-Channel: Two-channel variable polarization voltage; current/voltage converter for the polarographic oxygen sensor (POS); amplifyer with digital gain settings (1x, 2x, 4x, 8x); A/D converter; output in the range -10 V to 10 V. Integral component of the O2k-Main Unit.20040
O2k-Barometric Pressure TransducerO2k-Barometric Pressure Transducer, A/D converter and digital output to DatLab for continuous recording of barometric pressure [kPa or mmHg], integrated into the air calibration of the OroboPOS (MiPNet06.03 POS-calibration-SOP). Integral component of the O2k-Main Unit. The warranty on the accuracy of the signal obtained from the O2k-Barometric Pressure Transducer expires within three years.20050
O2k-Assembly KitThe O2k-Assembly Kit is a component of the O2k-Core, consisting of 2 O2k-Chambers (Duran glass), 2 PVDF Stirrer-Bars, 2 PVDF or PEEK O2k-Stoppers, O2k-Chamber Holders OroboPOS-Holders and OroboPOS-Connectors, and cables (power supply, USB-connection). Several components of the O2k-Assembly Kit are included in the O2k-Service Box either for shipment or for storage.20100
2 OroboPOSThe 2 OroboPOS set (two polarographic oxygen sensors, POS) is included in the O2k-Core, shipped with the O2k in the O2k-Service Box. For details, see OroboPOS.20600
OroboPOS.JPG
OroboPOS-Service KitOroboPOS-Service_Kit, with O2k-Service Box including all oxygen sensor service accessories for membrane mounting and service of the OroboPOS.20610-02
ServiceBox G 2.jpg
DatLabDatLab is the O2k-Software for Data Acquisition & Analysis, specifically developed for O2k high-resolution respirometry with the Oxygraph-2k. The newest DatLab version is included in the O2k-Core, and updates of DatLab are free of charge during the warranty period of the O2k.20700
DatLab
ISS-Integrated Suction SystemISS-Integrated Suction System: Suction pump 230 or 120 V with stainless steel housing, 2 liter waste bottle, filter and tubing; for siphoning off excess medium from the O2k-Stopper and for emptying the O2k-Chambers. The ISS is included as a standard component of the O2k-Core. Media containing living cells or microorganisms, various poisons (inhibitors, uncouplers) and mixtures of proteins and substrates are safely disposed off in the 2-litre waste bottle.

The suction pump (230 V or 120 V) is enclosed in a stainless steel housing, which holds a readily accessible mains switch, two removable receptacles for the tip of the tubing, an easily removable and safe connection to the gas filter which further connects to the fully stabilized waste bottle. The waste bottle with filter can be simply removed for emptying, cleaning and drying.

For specific country configurations, see Product ID 28101, 28102, 28103.
20810
ISS.jpg
O2k-Titration SetThe O2k-Titration Set consists of Hamilton microsyringes (6 x 10 mm3 and 3 spare plungers, 6 x 25 mm3, 2 x 50 mm3, 1 x 500 mm3), provided in the Syringe Storage Box with Syringe Labels, a set of two Syringe Racks with Syringe Collars, and a set of two Tube Racks. The O2k-Titration Set is a basic HRR-Accessory included in the O2k-Core.20820-02
O2k-Titration Set.JPG
O2k-CompendiumO2k-Compendium for high-resolution respirometry, consisting of the O2k-Manual and a USB flash drive with DatLab, O2k-Manual, O2k-Protocols, O2k-Publications, and info on O2k-Workshops. The O2k-Compendium is a component of the O2k-Core.20900
Logo OROBOROS INSTRUMENTS.jpg
O2k-Catalogue: O2k-Assembly Kit\Cables21### O2k-Catalogue: O2k-Assembly Kit\Cables21###21###
O2k-Main Power CableO2k-Main Power Cable, either O2k-Main Power Cable\230 V\Europe, O2k-Main Power Cable\120 V\US-CA, or O2k-Main Power Cable\230 V\AU-NZ. This item is standard component of the O2k-Assembly Kit (O2k-Core).21110
O2k-Main Power Cable\230 V\EuropeO2k-Main Power Cable\230 V\Europe. An O2k-Main Power Cable is included in the O2k-Assembly Kit.21111-01
O2k-Main Power Cable 230 V Europe.JPG
O2k-Main Power Cable\120 V\US-CAO2k-Main Power Cable\120 V\US-CA, USA and Canada (120 V). An O2k-Main Power Cable is included in the O2k-Assembly Kit.21112-01
O2k-Main Power Cable 120 V US-CA.JPG
O2k-Main Power Cable\230 V\AU-NZO2k-Main Power Cable\AU-NZ, Australia and New Zealand (230 V). An O2k-Main Power Cable is included in the O2k-Assembly Kit.21113-01
O2k-Main Power Cable 230 V AU-NZ.JPG
USB-Cable 2.0\Type A-BUSB-Cable 2.0\Type A-B for connecting the O2k-Main Unit (O2k-Series E upwards) to the USB port of a PC or laptop. This item is a standard component of the O2k-Assembly Kit (O2k-Core).21230-01
USB-Cable2.0 Type A-B.JPG
O2k-Catalogue: O2k-Assembly Kit\Main Unit22### O2k-Catalogue: O2k-Assembly Kit\Main Unit22###22###
O2k-Chamber HolderO2k-Chamber Holder (blue POM) for PVDF or PEEK stoppers, with O-ring\Viton\18x2 mm and V-ring\30-35-4.5 mm. After the O2k-Chamber is inserted into the copper block, the O2k-Chamber Holder is screwed on top of the chamber into the copper block to hold the chamber into a tight vertical position (O-ring) and prevent liquid to flow from the stainless steel housing into the space outside of the chamber (V-ring). Two units of this item are standard components of the O2k-Assembly Kit (O2k-Core), mounted on the O2k-Main Unit.22100-01
Chamber holder PVDF Stopper.jpg
PlayVideo.jpg A1 Insert O2k-Chamber
O-ring\Viton\18x2 mmO-ring\Viton\18x2 mm, mounted on the O2k-Chamber Holder.22120-01
Viton O-ring 18x2.jpg
V-ring\30-35-4.5 mmV-ring\30-35-4.5 mm, mounted on O2k-Chamber Holder.22130-02
V-Ring 30-35-4.5.JPG
OroboPOS-ConnectorOroboPOS-Connector (blue POM), with male connection to OroboPOS sensor head (POS) and with cable and male plug fitting into O2k-Main Unit. Two units of this item are standard components of the O2k-Assembly Kit (O2k-Core), mounted on the OroboPOS-Holders at the O2k-Main Unit.22200-01
POS connector and cable connection.jpg
OroboPOS-HolderThe OroboPOS-Holder (POS-Holder), made from blue POM, is screwed into the copper block of the O2k-Main Unit, guiding the OroboPOS-Connector with the OroboPOS sensor head (POS) to the O2k-Chamber, and keeping the OroboPOS-Connector in a fixed position for sealing the O2k-Chamber with the OroboPOS-Seal Tip. In addition, the OroboPOS-Holder fixes the O2k-Chamber in an accurate rotational position by pressing against the angular cut of the glass chamber. Two units of this item are standard components of the O2k-Assembly Kit (O2k-Core), mounted on the O2k-Main Unit.22300-01
Pos holder.JPG
O2k-Window FrameO2k-Window Frame: blue POM, with thread for fixation on the O2k-Main Unit, to be removed only for rare cleaning purposes and for front fixation of the Fluorescence-Control Unit, using the O2k-Window Tool. Two units of this item are standard components of the O2k-Assembly Kit (O2k-Core), mounted on the O2k-Main Unit.22400-01
O2k-Window Frame.JPG
O2k-Window ToolO2k-Window Tool for removing the blue O2k-Window Frame from the O2k-Main Unit, for rare cleaning purposes and for front fixation of the Fluorescence-Control Unit. This item is a standard component of the O2k-Assembly Kit (O2k-Core).22410-01
O2k-Window Tool.jpg
O2k-Fuse Power Plug\M2.5 A\5x20 mmO2k-Fuse Power Plug\M2.5 A\5x20 mm: This item is a standard component of the O2k-Assembly Kit (O2k-Core), mounted on the socket for the O2k-Main Power Cable, at the rear panel of the O2k-Main Unit.22510-01
Fuses mains.jpg
O2k-Catalogue: O2k-Chamber and Stirrers23### O2k-Catalogue: O2k-Chamber and Stirrers23###23###
O2k-ChamberO2k-Chamber: 16 mm inner diameter, Duran glass polished, with standard operation volume (V) of 2 cm3 (2 ml). Two units of this item are standard components of the O2k-Assembly Kit (O2k-Core). The optical properties of Duran allow application in the O2k-Fluorometer (Duran optical properties).23100-01
Glass chamber.jpg
PlayVideo.jpg A1 Insert O2k-Chamber
Stirrer-Bar\white PVDF\15x6 mmStirrer-Bar\white PVDF\15x6 mm, operated in the O2k-Chamber at constant stirring speed (standard is 750 rpm, or 12.5 Hz), to provide optimum mixing of the sample in the aqueous medium and ensure a stable signal of the polarographic oxygen sensor (OroboPOS) placed in a position of maximum current of the medium.


Two units of this item are standard components of the O2k-Assembly Kit (O2k-Core).

O2k-Core: 2 in O2k-Assembly Kit.
23210-01
Stirrer bar PVDF.jpg
Stirrer-Bar\black PEEK\15x6 mmStirrer-Bar\black PEEK\15x6 mm, for specific applications with light guides to minimize optical interference.23220-01
Stirrer-Bar black PEEK15x6 mm.JPG
O2k-Catalogue: Stoppers\conical Shaft\central Port24### O2k-Catalogue: Stoppers\conical Shaft\central Port24###24###
Stopper\black PEEK\conical Shaft\central PortStopper\black PEEK\conical Shaft\central Port: with conical shaft and one central capillary (with PTFE, graphite, carbon fiber), Volume-Calibration Ring (A or B) for volume adjustment 1.5 to 3.2 ml; 2 mounted O-rings (O-ring\Viton\12x1 mm). The black PEEK stoppers are required for optical O2k-MultiSensor Modules (O2k-Fluo_LED2-Module). Two units of this item are standard components of the O2k-Assembly Kit (O2k-Core).24000-01
Stopper black PEEK conical Shaft central Port.JPG
O-ring\Viton\12x1 mmO-ring\Viton\12x1 mm, for PVDF or PEEK O2k-Stoppers, box of 4 as spares. Two spare boxes of this product are standard components of the O2k-Assembly Kit (O2k-Core) as well as the O2k-TPP+ ISE-Module and the O2k-NO Amp-Module.24310-01
Viton O-ring for PVDF Stopper.jpg
Volume-Calibration RingVolume-Calibration Ring (A or B) PVDF for O2k-Stoppers, white; attached to the stoppers.2432A-01 or 2432B-01
Volume calibration ring A+B PVDF for Stopper.jpg
Cover-Slip\blackA Cover-Slip should be placed on top of the O2k-Stopper to minimize contamination and evaporation of liquid extruding from the capillary of the stopper. The Cover-Slips do not exert any direct effect on oxygen backdiffusion into the O2k-Chamber. Use the the Cover-Slip\black to avoid light penetration and disturbance of fluorescence signals and generally for optical measurements in the Oxygraph-2k. Two units of this item are standard components of the O2k-Assembly Kit (O2k-Core).24411-01
Cover-Slip black.JPG
Stopper-SpacerStopper-Spacer (or gas spacer) to set the O2k-Stopper into a standard position for a fixed gas phase above the aqueous phase in the O2k-Chamber, during air calibration or for injection of nitrogen, argon or oxygen into the gas phase. This item is a standard component of the O2k-Assembly Kit (O2k-Core).24420-01
Gas spacer for Stopper.jpg
Syringe\60 ml\Gas-InjectionSyringe\60 ml\Gas-Injection, 60 ml, with spacer and stainless steel needle, flat tip, for gas injection into the O2k-Chamber. This item is a standard component of the O2k-Assembly Kit (O2k-Core).24430-01
Gas injection syringe.jpg
O2k-Catalogue: OroboPOS components26### O2k-Catalogue: OroboPOS components26###26###
OroboPOSThe OroboPOS is a polarographic oxygen sensor (POS), with an amperometric mode of operation. The OroboPOS meets the highest quality criteria in terms of linearity, stability and sensitivity of the signal. The Clark type polarographic oxygen sensor (POS) remains the gold standard for measuring dissolved oxygen in biomedical, environmental and industrial applications over a wide dynamic oxygen range. It consists of a gold cathode, a silver/silverchloride anode and a KCl electrolyte reservoir separated from the sample by a 25 µm membrane (FEP). The main body of the OroboPOS is made of PEEK. With application of a polarization voltage (0.8 V), a current is obtained as an amperometric signal, which is converted to a voltage.26000-01
OroboPOS sensor head.jpg
O2k-Service BoxO2k-Service Box empty, contains components of the OroboPOS-Service Kit and the O2k-Assembly Kit O2k-Core.26101-02
OroboPOS-Seal TipOroboPOS-Seal Tip, black butyl rubber gasket with 3 mm pore. 4/Pck, for sealing the OroboPOS (sensor head) against the O2k-Chamber. Push the wetted OroboPOS-Seal Tip over the POS-sensor head, with the pore positioned centrally, not covering any peripheral area of the gold cathode. Do not stretch the gasket across the POS-sensor head. One pack (4 seal tips) of this product is a standard component of the OroboPOS-Service Kit (O2k-Core).26110-01
POS seal tip.jpg
OroboPOS-Membrane RingOroboPOS-Membrane Ring, PEEK, holds the membrane against the inner O-ring on the POS housing. For shipment in the O2k-accessory box, the OroboPOS is enclosed in a perspex housing. When the POS is uncsrewed from the blue base of the housing, the OroboPOS-Membrane Ring slides out from the POS shaft, and can be put in place with the OroboPOS-Mounting Tool during membrane application.26120-01
POS membrane holder ring.jpg
O-ring\Viton\8x1 mmO-ring\Viton\8x1 mm: on OroboPOS sensor head.26130-01
POS O-ring for sensor head or POS mounting tool.jpg
O-ring\Viton\9x1 mmO-ring\Viton\9x1 mm on OroboPOS-Mounting Tool.26131-01
POS O-ring for sensor head or POS mounting tool.jpg
OroboPOS-MembranesOroboPOS-Membranes, FEP 25 µm; 40/Pck. Two packages of this item are standard components of the OroboPOS-Service Kit (O2k-Core)26200-01
POS membranes.jpg
OroboPOS-Electrolyte PowderOroboPOS-Electrolyte Powder, KCl. This item is a standard component of the OroboPOS-Service Kit (O2k-Core).26300-01
POS Electrolyte powder.jpg
OroboPOS-Mounting ToolOroboPOS-Mounting Tool for application of OroboPOS-Membranes. It consists of two parts, (i) the membrane guide (larger diameter) and (ii) the membrane ring holder with O-ring\Viton\9x1 mm for holding the OroboPOS-Membrane Ring during membrane application. This item is a standard component of the OroboPOS-Service Kit (O2k-Core).26400-02
POS mounting tool for membrane application 02.JPG
OroboPOS-Polishing ClothOroboPOS-Polishing Cloth for cathode cleaning. This item is a standard component of the OroboPOS-Service Kit (O2k-Core).26510-01
POS polishing cloth for cathode cleaning.jpg
OroboPOS-Polishing PowderOroboPOS-Polishing Powder for cathode cleaning. This item is a standard component of the OroboPOS-Service Kit (O2k-Core).26520-01
POS polishing powder for cathode cleaning.jpg
Pen-Contact OilPen-Contact Oil, for stable low contact resistance between the OroboPOS head and the OroboPOS-Connector. This item is a standard component of the OroboPOS-Service Kit (O2k-Core).26550-01
Pen contact oil.jpg
O2-Zero PowderO2-Zero Powder, dithionite (Na2S2O4), for zero-oxygen calibration of the OroboPOS. This item is a standard component of the OroboPOS-Service Kit (O2k-Core).26600-01
O2-Zero Powder.jpg
Forceps for membrane applicationForceps for membrane application: for OroboPOS and ISE membrane application; do not use for tissue preparation. This item is a standard component of the OroboPOS-Service Kit (O2k-Core) and the O2k-TPP+ ISE-Module.26700-01
Forcep for membrane application.jpg
Pipette\Plastic\1 ml ungradedPipette\Plastic\1 ml ungraded, for filling electrolyte into the reservoir of the OroboPOS. This item is a standard component of the OroboPOS-Service Kit (O2k-Core).26800-01
Pipette Plastic 1 ml-ungraded.JPG
O2k-Catalogue: DatLab Acquisition & Analysis Software27### O2k-Catalogue: DatLab Acquisition & Analysis Software27###27###
DatLab-Upgrading to DatLab 6DatLab-Upgrading to DatLab 6: including free follow-up updates for DatLab 6 for the next two years27142-01
O2k-Catalogue: O2k-Core Accessories28### O2k-Catalogue: O2k-Core Accessories: ISS-Integrated Suction System, O2k-Titration Set28###28###
ISS-Integrated Suction System\230 V\EUISS-Integrated Suction System\230 V\EU: Suction pump 230 V See: ISS-Integrated_Suction_System28101-01
ISS.jpg
ISS-Integrated Suction System\120 V\US-CAISS-Integrated Suction System\120 V\US-CA, suction pump 120 V (USA and Canada). See: ISS-Integrated_Suction_System28102-01
ISS.jpg
ISS-Integrated Suction System\230 V\AU-NZISS-Integrated Suction System\230 V\AU-NZ, suction pump 230 V and plug for Australia and New Zealand. See ISS-Integrated Suction System.28103-01
ISS.jpg
ISS-Steel HousingISS-Steel Housing, a component of the ISS-Integrated Suction System.28110-01
ISS-Steel Housing.JPG
ISS-Waste BottleISS-Waste Bottle, 2-liter, component of the ISS-Integrated Suction System.28120-01
ISS-Waste Bottle.JPG
ISS-LidISS-Lid, for ISS-Waste Bottle, component of the ISS-Integrated Suction System.28130-01
ISS-Lid.JPG
ISS-Filter and TubingISS-Filter and Tubing, ISS-Integrated Suction System.28140-01
ISS-Filter and Tubing.JPG
Power O2k NumbersPower O2k Numbers: Single number to label the O2k in a Power O2k-Lab.28200-01
Power O2k Numbers.JPG
O2k-Catalogue: O2k-Compendium29### O2k-Catalogue: O2k-Compendium29###29###
O2k-MultiSensorWhen one (or more) analytical parameters are monitored simultaneously with oxygen concentration and oxygen flux in the O2k, this is an O2k-MultiSensor application. The O2k-Core fully supports the O2k-MultiSensor Modules.3####-##
O2k-Catalogue: TIP2k3#### O2k-Catalogue: TIP2k3####3####
Titration-Injection microPumpTitration-Injection microPump (TIP2k) for two-channel operation with the O2k-Core with automatic control by DatLab of programmable titration regimes and feedback control (oxystat, pH-stat). Included in the TIP2k-Module.31000-01
Titration-Injection-microPump.jpg
Electronic-TIP2k Upgrading\O2k-Main Unit Series A-DElectronic-TIP2k Upgrading\O2k-Main Unit Series A-D: not required for O2k-Core, the O2k-Main Unit has to be returned to the OROBOROS workshop.31103-00
Electronic-TIP2k Upgrading\O2k-Main Unit Series EElectronic-TIP2k Upgrading\O2k-Main Unit Series E: not required for O2k-Core, free of charge for Series E in conjunction with the purchase of the TIP2k-Module, the O2k-Main Unit has to be returned to the OROBOROS workshop.31104-00
Microsyringe\500 mm3\TIP2kMicrosyringe\500 mm3\TIP2k: Microinjection syringe for Titration-Injection microPump, 500 mm3 (µl), with spacers.31210-01
Microsyringe 500 mm3 TIP2k.JPG
Microsyringe\200 mm3\TIP2kMicrosyringe\200 mm3\TIP2k: Microinjection syringe for Titration-Injection microPump, 200 mm3 (µl), with spacers. Four units of this item are standard components of the TIP2k-Module.31220-01
Microsyringe200 mm3TIP2k.JPG
TIP2k-Needle SpacerTIP2k-Needle Spacers for microinjection TIP2k needle, silicone stops (200/Pkg.) with mounting tool. This item is a standard component of the TIP2k-Module.31310-01
80600-24 Spacers f. TIP2k needle.JPG
TIP2k Filter PapersTIP2k Filter Papers (package of 10) to be used for the stoppers during TIP2k titration for Instrumental oxygen background correction to avoid constant manual siphoning off of extruded liquid. One package is a standard component of the TIP2k-Module.31320-01
TIP2k Filter Papers.JPG
TIP2k-Needle Safety SupportTIP2k-Needle Safety Support: for safe storage of TIP2k-needles when not required during the experiment. This item is a standard component of the TIP2k-Module.31330-01
TIP2k-Needle Safety Support overview.JPG
O2k-Catalogue: O2k-MultiSensor4#### O2k-Catalogue: O2k-MultiSensor. O2k-MultiSensor Modules can be obtained with the O2k-Core or added later, and can be simply installed by the user.4####4####
MultiSensor-ConnectorMultiSensor-Connector: for separate reference electrode and ISE; only for O2k-Series B and Series C with MultiSensor electronic upgrading before 2011.40420-00
30420-24 MultiSensorConnector.JPG
MultiSensor-Preamplifier 1/100MultiSensor-Preamplifier 1/100: Required only for O2k-Series A-C, for application of NO (or other amperometric) sensors (single chamber mode of application).40430-00
30430--24 NO-Attachment.JPG
O2k-Catalogue: O2k-MultiSensor\General41### O2k-Catalogue: O2k-MultiSensor\General41###41###
Stopper-Shaft angular\white PVDF\side PortStopper-Shaft angular\white PVDF\side Port: angular base, for drilling additional custom-made ports for user-specified O2k-MultiSensor applications.41111-00
Stopper\black PEEK\conical Shaft\central+side 2.5 mm PortStopper\black PEEK\conical Shaft\central+side 2.5 mm Port, black PEEK (with PTFE, graphite, carbon fiber); 1 additional hole (2.5 mm); central titration port; conical bottom; including Volume-Calibration Ring (A or B); 2 mounted O-rings (O-ring\Viton\12x1 mm).41220-01
Stopper\white PVDF\angular Shaft\side+5 mm PortStopper\white PVDF\angular Shaft\side+5 mm Port: 1 additional hole (5 mm); side titration port; angular bottom; including Volume-Calibration Ring (A or B); 2 mounted O-rings (O-ring\Viton\12x1 mm).41252-01
Stopper\white PVDF\angual Shaft\side+6 mm PortStopper\white PVDF\angual Shaft\side+6 mm Port: 1 additional hole (6 mm); side titration port; angular bottom; including Volume-Calibration Ring (A or B); 2 mounted O-rings (O-ring\Viton\12x1 mm).41262-01
Stopper\white PVDF\conical Shaft\central+specified PortsStopper\white PVDF\conical Shaft\central+specified Ports: for O2k-MultiSensor applications with user-specific sensors; with additional holes custom-made, according to customer specification (max. 3.5 mm diameter); including Volume-Calibration Ring (A or B); 2 mounted O-rings (O-ring\Viton\12x1 mm).41312-01
Stopper\white PVDF\angular Shaft\side+specified PortStopper\white PVDF\angular Shaft\side+specified Port: with additional holes custom-made according to customer specification (max. 8 mm diameter); angular bottom; including Volume-Calibration Ring (A or B); 2 mounted O-rings (O-ring\Viton\12x1 mm).41314-01
O2k-Catalogue: TPP+ ISE-Module42### O2k-Catalogue: TPP+ ISE-Module42###42###
ISE-Service BoxISE-Service Box: for storage and shipment of the O2k-TPP+ ISE-Module or O2k-pH ISE-Module.42001-01
ISE-Service Box.JPG
ISE Package 1 TPP or CaO2k-TPP+ and Ca2+ ISE\1 Chamber: ISE-Package for 1 TPP+ and Ca2+ electrode.42010-01
ISE Package 1 TPP or Ca.JPG
Stopper\black PEEK\angular Shaft\side+6.2+2.6 mm PortStopper\black PEEK\angular Shaft\side+6.2+2.6 mm Port, for application with ISE; side titration port and two additional holes (6.2 mm and 2.6 mm); angular bottom; including Volume-Calibration Ring (A or B); 2 mounted O-rings (O-ring\Viton\12x1 mm). 2 included in O2k-TPP+ ISE-Module.42100-01
Stopper black PEEK angular Shaft side+6.2+2.6 mm Port.JPG
Stopper-NeedleStopper-Needle: Short needle for bubble extrusion from port of the ISE-stopper.42120-01
Stopper-Needle.JPG
Ion-Selective Electrode TPP+ and Ca2+Ion-Selective Electrode TPP+ and Ca2+: ISE with 6 mm outer diameter shaft, for Stopper\white PVDF\angular Shaft\side+6.2+2.6 mm Port. O2k-TPP+ ISE-Module: 2 ISE.42200-01
Ion-Selective Electrode TPP+ and Ca2+.JPG
ISE-Inner Glass ElectrodeISE-Inner Glass Electrode of ISE, with Ag/AgCl- and Pt-wire42212-01
ISE-Inner Glass Electrode.JPG
ISE-Membrane SealISE-Membrane Seal for Ion-Selective Electrode TPP+ and Ca2+.42213-01
ISE-Membrane Seal.JPG
ISE-Compressible TubeISE-Compressible Tube for Ion-Selective Electrode TPP+ and Ca2+.42214-01
ISE-Compressible Tube.JPG
ISE-Consumables Spares SetISE-Consumables Spares Set42250-01
ISE-Consumables Spares Set.JPG
ISE-TPP+ MembranesISE-TPP+ Membranes, PVC, 4 mm diameter, box of 5 membranes. O2k-TPP+ ISE-Module: 2 boxes per electrode.42270-01
ISE-TPP+ Membranes.JPG
ISE-Ca2+ MembranesISE-Ca2+ Membranes: PVC, 4 mm diameter, box of 5 membranes. To be used with the O2k-TPP+ ISE-Module. The ISE-Ca2+ Membranes have to be ordered separately.42280-01
Ca2+ membranes.jpg
ISE-Membrane Mounting ToolISE-Membrane Mounting Tool for Ion-Selective Electrode TPP+ and Ca2+. O2k-TPP+ ISE-Module: mounting tool included.42300-01
ISA-Membrane Mounting Tool.JPG
ISE-Filling SyringeISE-Filling Syringe with needle for Ion-Selective Electrode TPP+ and Ca2+.42310-01
ISE-Filling Syringe.JPG
Reference-Electrode\2.4 mmReference-Electrode\2.4 mm: 2.4 mm diameter glass shaft, for ISE.42400-01
Reference Electrode 2.4 mm.jpg
Replacement-BarrelReplacement-Barrel for Reference-Electrode\2.4 mm, 2.4 mm diameter glass.42401-01
Replacement-Barrel.jpg
Electrolyte\Reference-ElectrodeElectrolyte\Reference-Electrode for Reference-Electrode\2.4 mm42402-01
Electrolyte Reference-Electrode.jpg
O2k-Catalogue: pH-Electrode43### O2k-Catalogue: pH-Electrode43###
Stopper\black PEEK\conical Shaft\central+2.3+2.6 mm PortStopper\black PEEK\conical Shaft\central+2.3+2.6 mm Port: for pH and reference electrode, central titration port and two additional ports (2.3 mm and 2.6 mm); conical bottom; including Volume-Calibration Ring (A or B), 2 mounted O-rings (O-ring\Viton\12x1 mm). Two stoppers are included in the O2k-pH ISE-Module.43100-01
Stopper black PEEK conical Shaft central+2.3+2.6 mm Port.JPG
PH-Glass electrodepH-Glass electrode with BNC plug. Two pH electrodes are included in the O2k-pH ISE-Module.43200-01
PH-Glass Electrode.JPG
O2k-Catalogue: O2k-Fluorescence44### O2k-Catalogue: O2k-Fluorescence44###44###
Fluorescence-Service BoxFluorescence-Service Box44001-01
Fluorescence-Service Box.JPG
Fluorescence-Control UnitFluorescence-Control Unit with O2k-Front Fixation, Current-Control (O2k-Chamber A and B) for regulation of light intensity of the LED in the fluorescence sensors. This item is a standard component of the O2k-Fluorescence LED2-Module.44100-01
Fluorescence-Control Unit lettered.jpg
Fluorescence-SensorFluorescence-Sensor: LED with specified wavelength, photodiode, Filter-Cap attached with specific optical filter for the LED and/or photodiode. See Fluorescence-Sensor Green and Fluorescence-Sensor Blue.442##
Fluorescence-Sensor.jpg
Fluorescence-Sensor GreenFluorescence-Sensor Green: excitation LED 525 nm, photodiode, Filter-Cap equipped with Filter Set AmR for Amplex UltraRed measurements when delivered. Two units of this item are standard components of the O2k-Fluo LED2-Module.44210-01
Fluorescence-Sensor Green.JPG
Fluorescence-Sensor BlueFluorescence-Sensor Blue: excitation LED 465 nm, photodiode, Filter-Cap equipped with Filter Set Saf for measurement of mitochondrial membrane potential with Safranin when delivered. Filter sets for Magnesium green® / Calcium green® measurements are included. Two units of this item are standard components of the O2k-Fluo LED2-Module.44220-01
Fluorescence-Sensor Green.JPG
Filter-CapFilter-Cap: Each Fluorescence-Sensor Green and Fluorescence-Sensor Blue is equipped with a removable Filter-Cap for exchange of optical filters for the optical pathways from the LED to the sample and from the sample to the photodiode.44310-01
Filter-Cap.JPG
Filter Set AmRFilter Set AmR: Set of filters for the determination of H2O2 production with Amplex® UltraRed. These filters should be used together with Fluorescence-Sensor Green. The filter set consists of 6 LED filters (round) and 6 photodiode filters (rectangular). One pair of these filters is attached to Fluorescence-Sensor Green when delivered as part of the O2k-Fluorescence LED2-Module. One filter set is a standard component of the O2k-Fluorescence LED2-Module.44321-01
Filter Set AmR.JPG
Filter Set SafFilter set Saf: Set of filters for the (qualitative) determination of mitochondrial membrane potential with Safranin. These filters should be used together with Fluorescence-Sensor Blue. The filter set consists of 6 LED filters (round) and 6 photodiode filters (rectangular). One pair of these filters is attached to Fluorescence-Sensor Blue when delivered as part of the O2k-Fluorescence LED2-Module.


One filter set is a standard component of the O2k-Fluorescence LED2-Module.
44322-01
Filter Set Saf.JPG
Filter Set MgG / CaGFilter set MgG / CaG: Set of filters for the determination of concentraions of Mg2+ or Ca2+ with the fluorophores Magnesium green and Calcium green, respectively. These filters should be used together with Fluorescence-Sensor Blue. The filter set consists of 6 LED filters (round) and 6 photodiode filters (rectangular). One filter set is a standard component of the O2k-Fluorescence LED2-Module.44323-01
Filter Set MgG CaG.JPG
O2k-Catalogue: NO-Amp-Module46### O2k-Catalogue: NO-Amp-Module46###46###
Stopper\black PEEK\conical Shaft\central Port\peripheral 2.3 mm PortStopper\black PEEK\conical Shaft\central+peripheral 2.3 mm Port: for potentiometric O2k-MultiSensor applications (NO, H2S, H2O2); 1 additional port (2.3 mm); central titration port; conical bottom; including Volume-Calibration Ring (A or B); 2 mounted O-rings (O-ring\Viton\12x1 mm). O2k-MultiSensor: 2 in O2k-NO Amp-Module.46100-01
Stopper black PEEK conical Shaft central Port peripheral 2.3 mm Port.JPG
O2k-Catalogue: Core-Accessories and Auxiliary HRR-Tools5#### O2k-Catalogue: Core-Accessories and Auxiliary HRR-Tools5####5####
O2k-Catalogue: Titration-Tools51### O2k-Catalogue: Titration-Tools51###51###
Microsyringe\10 mm3 51/0.13 mmHamilton Microsyringe\10 mm3 51/0.13 mm for manual titrations, 10 mm3 volume; injection needle fixed: 51 mm length, 0.13 mm inner diameter. O2k-Core: 6 included in the O2k-Titration Set.51010-01
Hamilton Syringes for Manual Titration.jpg
Plunger\10 mm3Plunger\10 mm3 for Microsyringe\10 mm3 51/0.13 mm, spare. O2k-Core: 3 in O2k-Titration Set.51011-01
Plunger 10 mm3.JPG
Microsyringe\25 mm3 51/0.15 mmHamilton Microsyringe\25 mm3 51/0.15 mm for manual titrations, 25 mm3 volume; injection needle fixed: 51 mm length, 0.15 mm inner diameter. O2k-Core: 6 in O2k-Titration Set.51025-01
Microsyringe 25 mm3 51 0.15 mm.JPG
Plunger\25 mm3Plunger\25 mm3 for Microsyringe\25 mm3 51/0.15 mm, spare.51026-01
Plunger 25 mm3.JPG
Microsyringe\50 mm3 51/0.15 mmHamilton Microsyringe\50 mm3 51/0.15 mm for manual titrations, 50 mm3 volume; injection needle fixed: 51 mm length, 0.15 mm inner diameter. O2k-Core: 2 in O2k-Titration Set.51050-01
Microsyringe 100 mm3 51 0.41 mm - Kopie.JPG
Plunger\50 mm3Plunger\50 mm3 for Microsyringe\50 mm3 51/0.15 mm, spare.51051-01
Plunger 50 mm3.JPG
Microsyringe\100 mm3 51/0.41 mmHamilton Microsyringe\100 mm3 51/0.41 mm for manual titrations, 100 mm3 volume; injection needle fixed: 51 mm length, 0.41 mm inner diameter. These syringes are not included in our standard set, but are recommended for injections of suspensions of isolated mitochondria.51100-01
Microsyringe 100 mm3 51 0.41 mm - Kopie.JPG
Syringe\500 mm3 51/0.41 mmHamilton Syringe\500 mm3 51/0.41 mm for manual titrations, 500 mm3 volume; injection needle fixed: 51 mm length, 0.41 mm inner diameter; for injections of suspensions of isolated mitochondria and filling of the Microsyringe\200 mm3\TIP2k. O2k-Core: 1 included in the O2k-Titration Set.51500-01
Syringe 500 mm3 51 0.41 mm.JPG
Syringe RacksSyringe Racks: stainless steel; for proper placement of eight Hamilton microsyringes during HRR experiments; package of two (for a total of 16 microsyringes). One package of two Syringe Racks and two Tube Racks is a standard component of the O2k-Titration Set.51610-01
Syringe Racks.JPG
Syringe CollarsSyringe Collars (package of 20) for Hamilton microsyringes: for correctly storing the microsyringes in the Syringe Racks. One package is a standard component of the Syringe Racks.51611-01
Syringe Collars.JPG
Tube RacksTube Racks: stainless steel, accomodating four 50-ml tubes, for cleaning of microsyringes, cleaning and storage of stoppers during cleaning of the O2k-Chambers; package of two (for a total of eight tubes). One package of two Tube Racks and two Syringe Racks is a standard component of the O2k-Titration Set.51620-01
Tube Racks.JPG
Syringe Storage BoxSyringe Storage Box: for storing the Hamilton microsyringes; incl. Syringe Labels, MiPNet19.14 SOP Hamilton microsyringes and MiPNet09.12 O2k-Titrations. One item is a standard component of the O2k-Titration Set.51630-01
Syringe Storage Box.jpg
Syringe LabelsSyringe Labels: set of labels with standard abbreviations (see O2k-Titrations). One set of labels is a standard component of the Syringe Storage Box.51631-02
Syringe Labels.JPG
Titration Set UpgradeThe Titration Set Upgrade consists of the new items of the O2k-Titration Set for upgrading your original set (consisting only of Hamilton microsyringes). The upgrade consists of the Syringe Storage Box with Syringe Labels, a set of two Syringe Racks with Syringe Collars, and a set of two Tube Racks as well as an additional syringe (1 x 500 mm3).51910-01
O2k-Titration Set.JPG
O2k-Catalogue: PBI-Shredder52### O2k-Catalogue: PBI-Shredder52###52###
PBI-Shredder SG3PBI-Shredder SG3 for tissue homogenate preparation, heavy duty high torque SG3 driver with convertible handle, SG3 base with 3 position force setting lever (FSL), battery charger and two lithium ion batteries. The PBI-Shredder SG3 is included in the PBI-Shredder HRR-Set. Select 230 V or 120 V. OROBOROS INSTRUMENTS: world-wide distributor.52100
PBI-Shredder SG3.jpg
Shredder-Kit BoxShredder-Kit Box: box for storage and shipping, for PBI-Shredder SG352101-01
PBI-Shredder SG3\230 VPBI-Shredder SG3\230 V52110-01
PBI-Shredder SG3\120 VPBI-Shredder SG3\120 V52120-01
Shredder-Tube Cap ToolShredder-Tube Cap Tool: component of PBI-Shredder_HRR-Set.52130-01
Shredder-Tube Cap Tool.JPG
Shredder-Tube Ram ToolShredder-Tube Ram Tool: component of PBI-Shredder_HRR-Set.52140-01
Shredder-Tube Ram Tool.JPG
Shredder-Accessory BoxShredder-Accessory Box: 71x335x240 mm inner dimensions, for storage and shipping of Shredder accessories.52201-01
Shredder-TubesShredder-Tubes: consisting of Shredder Tube FT500-PS with Lysis Disk, serrated Shredder-Ram and Shredder-Screw Cap, coral colour (Box of 100) and Shredder Tube FT500-PMS with Lysis Disk, serrated Shredder-Ram and Shredder-Screw Cap, coral colour (Box of 100). 1 box of each is included in the PBI-Shredder HRR-Set.52210-01, 52220-01
Shredder-Tube Analyt Biochem.jpg
O2k-Catalogue: Microbalance Mettler-Toledo53### O2k-Catalogue: Microbalance Mettler-Toledo53###53###
Microbalance 120 gMicrobalance 41 g to 120 g; 0.01 mg / 0.1 mg display; particularly for wet weight determination of permeabilized fibres.53100-01
Microbalance 120 g.jpg
Microbalance-Transport CaseMicrobalance transport case.53300-01
Microbalance-Transport Case.jpg
O2k-Catalogue: HRR-Dissection Tools54### O2k-Catalogue: HRR-Dissection Tools54###54###
Forceps\stainless Steel\straight Tip\sharpForceps\stainless Steel\straight Tip\sharp: for tissue preparation, stainless steel, antimagnetic. One pair is recommended for insertion of the sample into the O2k-Chamber and for handling in combination with Forceps\stainless Steel\rounded Tip\sharp. Set: in HRR-Dissection Set and PBI-Shredder HRR-Set.54210-01
Forcep for tissue preparation straight tip.jpg
Forceps\stainless Steel\rounded Tip\sharpForceps\stainless Steel\reounded Tip\sharp: for tissue preparation, stainless steel, antimagnetic. One pair is recommended for placing the tissue sample onto the microbalance and for handling in combination with Forceps\stainless Steel\straight Tip\sharp. Set: in HRR-Dissection Set.54220-01
Forcep for tissue preparation rounded tip.jpg
Forceps\stainless Steel\angular Tip\fineForceps\stainless Steel\angular Tip\fine: for tissue preparation, stainless steel. Two pairs are used particularly for muscle fibre separation. Set: 2 in HRR-Dissection Set.54230-01
Forcep for tissue preparation angular tip.jpg
Scissors\stainless steel\straight Tip\sharpScissors\stainless steel\straight Tip\sharp, included in PBI-Shredder HRR-Set and HRR-Dissection Set.54310-01
Scissors stainless steel straight Tip sharp.jpg
Motic MicroscopeMotic Microscope SMZ-171 TP: for preparation of permeabilized fibres; compact and light stereo microscope, Greenough optical system, switching power supply for use worldwide (100-240V); including auxiliary ESD objective 2.0X(38.6mm).54500-01
Motic Microscope.jpg
O2k-WorkshopsOROBOROS O2k-Workshops are organized as international oxygraph courses (IOC) on high-resolution respirometry since 1991. These range from four full-day training courses to conference lunch presentations of the OROBOROS Oxygraph-2k and O2k-Fluorometer.7####
O2k-Workshops.png
MitoFit Coaching Days Innsbruck
MitoFit Laboratory

By organizing MitoFit Coaching Days Innsbruck, the OROBOROS-team responds to increasing demands for training in high-resolution respirometry (HRR) and O2k-Fluorometry beyond the capacity of our regular O2k-Workshops. MitoFit Coaching Days are offered in the OROBOROS MitoFit Laboratory according to demand for four to six participants (or labs). Experts provide training for quality control in high-resolution respirometry, aimed at standardization of SUIT protocols and fostering proficiency to generate experimental data of assured high quality as required for a data base on mitochondrial physiology.

The flexible programme is adjusted to the individual requirements of the participants, with specific coaching blocks particularly on instrumental setup and maintenance, instrumental quality control, MitoFit proficiency testing using standardized mitochondrial reference samples, DatLab analysis, SUIT protocols and experimental design, normalization of flux and data reporting, O2k-Fluorometry for measurement of hydrogen peroxide, measurement of mitochondrial membrane potential with fluorometric and potentiometric methods, measurement of respiration and acidification, quality control management in HRR. The MitoFit Coaching Days help participants to get prepared for their projects on HRR, even if the regular O2k-Workshops are fully booked.
7####
O2k-Workshops.png
O2k-Workshop\Registration waivedO2k-Workshop\Registration waived
  • A registration fee is waived in conjunction with the purchase of the O2k-Core (academic discount), valid during the O2k-Warranty Period.
70000
O2k-Workshops.png
O2k-Workshop\4 Days\StandardO2k-Workshop\4 Days\Standard: introductory O2k-Workshop and training course (4 Days), standard registration. Module: A registration fee is waived in conjunction with the purchase of the O2k-Core (academic discount), valid during the O2k-Warranty Period.70004-01
O2k-Workshop\4 Days\StudentO2k-Workshop\4 Days\Student: introductory training course (4 Days), student registration.70004-02
MitoFit Coaching Days - BasicMitoFit Coaching Days - Basic: individual introductory training course (3 Days), standard registration, 4-6 participants. One registration fee is waived in conjunction with the purchase of the O2k-Core (academic discount), valid during the O2k-Warranty Period.70020-01
Workshop 3 days StandardO2k-Workshop (3 days), standard registration.71003-01
Workshop 3 days StudentO2k-Workshop (3 days), student registration.71003-02
Workshop 7 days StandardOxygraph-2k & O2k-MultiSensor Workshop (7 Days), standard registration; combined introductory and advanced O2k-MultiSensor Workshop.71007-01
Workshop 7 days StudentO2k-Basic & O2k-Multisensor-Workshop (7 Days), student registration; combined introductory and advanced O2k-MultiSensor Workshop.71007-02
Oxygraph-2k start-up serviceO2k start-up service, O2k training course (3 days). In most cases, the O2k-Manual provides sufficient detail for setting up the O2k and starting measurements, particularly in conjunction with participation in an introductory O2k-Workshop. For specific requirements, however, a start-up visit by a scientific application specialist supports a highly efficient start of a project.72003-01
Oxygraph-2k scientific support serviceO2k scientific support visit (4 days) by an O2k-application specialist provides scientific support in specific areas of applications, including help with sample preparation, design and testing of titration protocols (including SUIT protocols), and DatLab analysis.72004-01
PR-Accessories98### PR-Accessories98###98###
T-Shirt: MitoFitT-Shirt MitoFit: OROBOROS Logo on front, MitoFit Logo on back.98000-01
Tshirt MitoFit OROBOROS.jpg
T-Shirt: Oroboros black/organic cottonT-Shirt Oroboros black/organic cotton: An OROBOROS on the front.98010-01
Packing99### Packing99###99###
Packing\O2k-Box 1+2Packing\O2k-Box 1+2 for shipping the O2k-Core. O2k-WorldWide delivery, insurance and handling are included in the O2k-Core.99000
Packing\O2k-Box 1Packing\O2k-Box 1: for shipment of the O2k-Main Unit, with polystyrene inlets. Keep the original packing material safely stored, for any future shipping purposes of the O2k-Main Unit.99010-01
Packing O2k-Box1.JPG
Packing\Peli CasePacking\Peli Case: Watertight, crushproof, and dust proof case for safe transportation of the O2k:

Retractable extension handle, Strong polyurethane wheels with stainless steel bearings, Easy open Double Throw latches, Open cell core with solid wall design - strong, light weight, O-ring seal, Automatic Pressure Equalization Valve, Fold down handles, Stainless steel hardware and padlock protectors, 4 level Pick N Pluck™ with convoluted lid foam, Special foam inlets for O2k.

Interior Dimensions: 21.48" x 16.42" x 12.54" (54.5 x 41.7 x 31.8 cm)
99012-01
Packing Peli Case.jpg
Packing\O2k-Box 2Packing\O2k-Box 2, for shipment of accessories.99020-01
Packing O2k-Box2.JPG
TIP2k and O2k-upgrade\BTIP2k and O2k-Upgrade\B: Titration-Injection microPump TIP2k, including the electronic upgrade of the O2k-main unit returned to workshop (Series B-D).Discontinued
Stopper-Shaft conical\white PVDF\central PortStopper-Shaft conical\white PVDF\central Port: PVDF shaft with one central capillary and conical base, receptacle on the top for collecting excess medium during closing the O2k-Chamber and during titration; component of Stopper\white PVDF\conical Shaft\central Port.Discontinued
TIP2k cooling boxTIP2k-Cooling Box: Cooling box for TIP2k syringes.Discontinued
PH combination electrode 150/6 mmpH combination electrode, 150 mm shaft, 6 mm diameter, incl. connection cable with BNC plug. Discontinued
Cover-SlipA Cover-Slip should be placed on top of the O2k-Stopper to minimize contamination and evaporation of liquid extruding from the capillary of the stopper. The Cover-Slips do not exert any direct effect on oxygen backdiffusion into the O2k-Chamber. Use the Cover-Slip\black (Product ID 24411-01) for optical measurements in the O2k.Discontinued
TIP2k electronic upgradeTIP2k-Electronic Upgrade, to add the Titration-Injection microPump TIP2k as a modular component at any time - standard component of the O2k-Core, discontinued as a separate optional component.Discontinued
PH combination electrode 70/5 mmpH-Combination Electrode\70/5 mm, 70 mm shaft, 5 mm diameter, for 30251-24 stopper.
  • Replaced by O2k-pH ISE-Module.
  • Discontinued
    DatLab-Upgrading\4.x-5.2DatLab-Upgrading\4.1-5.2: Upgrading DatLab 4.x to 5.2, incl. O2k-Manual, with free follow-up updates of DatLab 5.2. Discontinued: see higher DatLab version.Discontinued
    TrolleyAluminium trolley (700x500x60 mm); carrying capacity 120 kg; incl. packing box; for transport of O2k.Discontinued
    RS232-CableRS232 0-modem-Cable for connecting the O2k-Main Unit to the PC or laptop with DatLab installed. When using DatLab 5, this cable is replaced by USB-Cable 2.0\Type A-B for O2k-Series E upwards.Discontinued
    RS232-Cable.JPG
    Microbalance 220 gMicrobalance 81 g to 220 g; 0.01 mg / 0.1 mg display; particularly for wet weight determination of permeabilized fibres.Discontinued
    Microbalance 220 g.jpg
    USB-RS232 Serial AdapterUSB-RS232 Serial Adapter, for connecting the RS232-Cable attached to the O2k-Main Unit (Series A-D) to the USB port of the PC or laptop. This is not required for O2k-Series E, nor when using a PC or laptop with a serial RS232 port.Discontinued
    Stopper\white PVDF\conical Shaft\central PortStopper\white PVDF\conical Shaft\central Port: for closing the O2k-Chamber, with one capillary and conical basis; including Volume-Calibration Ring (A or B) for volume adjustment (1.5 to 3.2 ml); 2 mounted O-rings (O-ring\Viton\12x1 mm).Discontinued
    30221-24 PVDF Stopper.jpg
    Stopper\white PVDF\angular Shaft\side+6.2+2.6 mm PortStopper\white PVDF\angular Shaft\side+6.2+2.6 mm Port, for application with ISE; side titration port and two additional holes (6.2 mm and 2.6 mm); angular bottom; including Volume-Calibration Ring (A or B); 2 mounted O-rings (O-ring\Viton\12x1 mm).Discontinued
    Stopper white PVDF angular Shaft side+6.2+2.6 mm Port.JPG
    OROBOROS support system
    OROBOROS support

    O2k-technical support

    This information is part of O2k-technical support and open innovation.